SHERBURNE, NY —
OSHA Inspection: CHENANGO VALLEY TECHNOLOGIES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHENANGO VALLEY TECHNOLOGIES INC. in 328 ROUTE 12B, SHERBURNE, NY 13460 (NAICS 326199). OSHA activity number 338851645.
Where did this inspection happen?
- Establishment
- CHENANGO VALLEY TECHNOLOGIES INC.
- Site address
- 328 ROUTE 12B
- City
- SHERBURNE
- State
- NY
- ZIP
- 13460
- Mailing
- P.O. BOX 1038, SHERBURNE, NY 13460
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 40
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2083.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): a) Molding Dept., on or about 2/13/13: Overhead storage area, approximately 9 feet from floor level, was not provided with guardrails. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.36 H02
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2083.00 Reduced
General-duty citation text
29 CFR 1910.36(h)(2): The outdoor exit route was not covered when snow or ice is likely to accumulate along the route: a) Tool Room, on or about 2/13/13: The outdoor exit route was not covered in that there was ice and snow buildup outside the exit door preventing free escape. b) Injection Molding Dept., by press #8, on or about 2/13/13: The outdoor exit route was not covered in that there was ice and snow buildup outside the exit door preventing free escape. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Tool Room, on or about 2/13/13: Exit door was blocked by ice and snow. b) Molding Dept., on or about 2/13/13: Exit door was blocked by ice and snow. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Molding Dept., near press #8, on or about 2/13/13: Door used as an exit to the outside was not marked with an exit sign. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At the establishment, on or about 2/13/13: There were no written specific procedures for employees performing servicing and/or maintenance on various equipment, including, but not limited to injection molding machines, grinders, air compressors, etc. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Molding Dept., on or about 2/13/13: Ingoing nip points on a Cincinnati injection molding machine #21 was not adequately guarded at the ejectors area in that the guard was broken. b) Tool Room, on or about 2/13/13: Rotating chucks on a 5 speed bench drill press and a Formosa radial drill were not guarded. c) Tool Room, on or about 2/13/13: Unused portion of blade on a Roll In bandsaw was not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $1785.00 · Current $1250.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) Molding Dept., on or about 2/13/13: A circuit breaker panel A3 behind Press #16 had one blank missing. b) Molding Dept., on or about 2/13/13: A circuit breaker panel behind press #20 did not have the blanks secured in place in that the blanks were not tightly installed to cover all openings. c) Molding Dept., on or 2/13/13: A knockout plug was missing on the disconnect switch for the Cumberland grinder at press #20. d) Molding Dept., on or about 2/13/13: A knockout plug was missing on a four way receptacle outlet at the Van Dorn press #13. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
More inspections at CHENANGO VALLEY TECHNOLOGIES INC.
SHERBURNE, NY—2025-07-18
CHENANGO VALLEY TECHNOLOGIES INC.
SHERBURNE, NY—2023-02-09 00:00:00
CHENANGO VALLEY TECHNOLOGIES INC.
SHERBURNE, NY—2008-10-16 00:00:00
CHENANGO VALLEY TECHNOLOGIES INC.
View CHENANGO VALLEY TECHNOLOGIES INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 338851645.