Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: OMNI COMPONENTS CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OMNI COMPONENTS CORP. in 46 RIVER ROAD, HUDSON, NH 03051 (NAICS 332710). OSHA activity number 339051187.

Watch Omni Components Corp. — free Get an email when a new federal OSHA severe-injury report for Omni Components Corp. is published. One employer, no account, unsubscribe in one click.
Site address
46 RIVER ROAD
City
HUDSON
State
NH
ZIP
03051
Mailing
46 RIVER ROAD, HUDSON, NH 03051
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
82
Ownership type
A

8 citations on file for this inspection.

1910.132 D01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment     (a) Shop - An assessment was not performed on the hazards associated with the Met-Kut 755 and Crystal Clean Premium 142 Mineral Spirits.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.1200 H01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): 29 CFR 1919.1200(h)(1):  Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:    (a) Shop - Employees were not trained in the use of gloves while working with hazardous chemicals.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1500.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) Shop - The employer did not have a Lock-out / Tag out program for the CNC machines with more than one hazardous energy source.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3500

1910.215 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    (a) Shop - The bench grinders work rest were not adequately adjusted.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.215 B09

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): 29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  (a) Shop - The tongue guard on the grinder was not adequately adjusted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.242(b): Compressed air, that was not reduced to less than 30 p.s.i., was used for cleaning purposes without effective chip guarding and personal protective equipment.    (a) Shop - The air receivers used for cleaning were at 100 p.s.i.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) Shop - Electrical plugs had damaged sheathing.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.303 B02

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) Shop - The fourway outlet box was not listed and labeled for external use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View OMNI COMPONENTS CORP.'s full OSHA safety record →