OSHA Inspection: HOME DEPOT #1518

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOME DEPOT #1518 in 2250 SOUTHGATE RD, COLORADO SPRINGS, CO 80906 (NAICS 444110). OSHA activity number 339068165.

Watch Home Depot #1518 — free Get an email when a new federal OSHA severe-injury report for Home Depot #1518 is published. One employer, no account, unsubscribe in one click.
Establishment
HOME DEPOT #1518
Site address
2250 SOUTHGATE RD
City
COLORADO SPRINGS
State
CO
ZIP
80906
Mailing
2250 SOUTHGATE RD, COLORADO SPRINGS, CO 80906
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
10000
Ownership type
A

2 citations on file for this inspection.

1910.303 B01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a)  On or about May 15, 2013, and at times prior, employees were exposed to electrical arcing hazards where the outer jacket of the battery charging cable on the Raymond pallet jack (serial no. 112-03-48805) was damaged;  b) On or about May 15, 2013, and at times prior, employees were exposed to electrical shock hazards where the receptacle for the battery charger on the JLG Electric Ladder (EL 1) was damaged.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) On or about May 15, 2013, and at times prior, employees were exposed to electrical shock hazards where the cords for the battery chargers on JLG Electric Ladders EL 2 and EL 4 did not have adequate strain relief at the connections of the cords and the plugs.     Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").