TAMUNING, GU —
OSHA Inspection: AMERICA'S BEST ELECTRICMART, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICA'S BEST ELECTRICMART, INC. in UNIT D, 129 WEST HARMON INDUSTRIAL PARK RD., TAMUNING, GU 96913 (NAICS 423610). OSHA activity number 339083883.
Where did this inspection happen?
- Establishment
- AMERICA'S BEST ELECTRICMART, INC.
- Site address
- UNIT D, 129 WEST HARMON INDUSTRIAL PARK RD.
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- UNIT D, 129 WEST HARMON INDUSTRIAL PARK RD., TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423610
- Employees
- 13
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Warehouse loft above office: On May 24, 2013, there was no midrail protecting employees working in the loft area from falling to the warehouse floor.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.37 B06
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: Warehouse back exit: On May 24, 2013, the exit sign over the door was not illuminated.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Warehouse: On May 24, 2013, the fire extinguisher located near the back exit was not subjected to a monthly visual inspection and was discharged.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.178 P01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s). Establishment: On May 24, 2013, the Caterpillar Serial Number AT83C01581 forklift rear tires were defective.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: Establishment: On May 24, 2013, a daily inspection was not conducted on the Caterpillar Serial Number AT83C01581 forklift with rear tires that were defective.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Warehouse floor, near front office: On May 24, 2013, the electric circuit breaker panelboard was missing a switch plug.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.305 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: Warehouse floor, next to Z1100e Security Control Box: On May 24, 2013, the electric circuit breaker panelboard was missing a panel front.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at AMERICA'S BEST ELECTRICMART, INC.
TAMUNING, GU—2014-11-10 00:00:00
AMERICA'S BEST ELECTRICMART, INC.
View AMERICA'S BEST ELECTRICMART, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423610)
FAIRFIELD, CA—2026-07-10
MAIN ELECTRIC SUPPLY
SANTA ANA, CA—2026-07-06
SAF-T-CO SUPPLY INC.
COLUMBUS, IN—2026-07-02
OPTIMAS OE SOLUTIONS
EUGENE, OR—2026-06-03
317744393 - CENTURY LIGHTING INC
MILPITAS, CA—2026-06-02
CONTRACTORS ELECTRICAL DISTRIBUTORS
More inspections in GU
BARRIGADA, GU—2026-01-22
DURI CORPORATION
TAMUNING, GU—2026-01-21
DLR CORPORATION
BARRIGADA, GU—2026-01-21
DURI CORPORATION
TAMUNING, GU—2026-01-20
MG CONSTRUCTION COMPANY
BARRIGADA, GU—2026-01-20
PFM -VERTEX-LMS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339083883.