2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: RJF INTERNATIONAL CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RJF INTERNATIONAL CORPORATION in 716 INDUSTRIAL PARK ROAD, MUNCY, PA 17756 (NAICS 326113). OSHA activity number 339106726.

Watch RJF International Corporation — free Get an email when a new federal OSHA severe-injury report for RJF International Corporation is published. One employer, no account, unsubscribe in one click.
Site address
716 INDUSTRIAL PARK ROAD
City
MUNCY
State
PA
ZIP
17756
Mailing
716 INDUSTRIAL PARK ROAD, MUNCY, PA 17756
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326113
Employees
62
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and crushed-by hazards created by metal storage rack systems that were not anchored to the concrete floor. a) Wall Talker Warehouse and Main Warehouse, 716 Industrial Park Road, Muncy PA: Employees placed or removed materials and products with powered industrial trucks onto pallet rack systems that were not anchored to the concrete floor. Employees were potentially exposed to struck-by and crushed-by hazards in the event of a pallet rack system collapse, as observed on or about June 7, 2013.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3400

1910.178 L04 III

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $3400.00
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years. a) Facility, 716 Industrial Park Drive, Muncy, PA: Employees operated powered industrial trucks (forklifts) daily and did not receive an evaluation of their ability to safely operate the equipment a minimum of at least once every three years. Employees were exposed to possible struck-by and crushed-by hazards from forklifts, as observed on or about June 7, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
  • — I (S) $3400
  • — Z (S) $3400

1910.242 B

Other-than-serious 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1000.00 Reduced
29 CFR 1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  a) Southernmost Dock Door, Wall Talkers Warehouse, 716 Industrial Park Road, Muncy, PA: Compressed air hose was used by employees to clean dust from dry erase wall covering and roll inspection rack. Employees were exposed to struck-by hazards caused by high pressure air, on or about June 7, 2013.  b) Aluminum Area, Main Warehouse, 716 Industrial Park Road, Muncy, PA: Compressed air hose was used by employees to clean dust and aluminum cuttings from aluminum parts and aluminum saw. Employees were exposed to struck-by hazards caused by high pressure air, on or about June 7, 2013.  c) Thermoformer, Thermoforming Department, 716 Industrial Park Road, Muncy, PA: Compressed air hose was used by employees to clean dust and PVC cuttings from PVC parts. Employees were exposed to struck-by hazards caused by high pressure air, on or about June 7, 2013.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $2550

1910.147 C06 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  a) Facility, 716 Industrial Park Drive, Muncy, PA: The employer did not conduct a periodic inspection of the machine specific procedures where and when employees performed servicing and maintenance on equipment. Employees were potentially exposed to the unexpected energizing, start up or release of stored energy in the event that the energy control procedures were inadequate, not being properly implemented, and/or that employees did not understand roles and responsibilities. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View RJF INTERNATIONAL CORPORATION's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339106726.