BERWICK, ME —
OSHA Inspection: BERWICK IRON & METAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BERWICK IRON & METAL, INC. in 106 ROUTE 236, BERWICK, ME 03901 (NAICS 423930). OSHA activity number 339112849.
Where did this inspection happen?
- Establishment
- BERWICK IRON & METAL, INC.
- Site address
- 106 ROUTE 236
- City
- BERWICK
- State
- ME
- ZIP
- 03901
- Mailing
- P.O. BOX 366, BERWICK, ME 03901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 14
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.67 C02 V
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.67(c)(2)(v): A body belt/harness was not worn and a lanyard attached to the boom or basket when working from an aerial lift: At the Facility - Operators of the Genie aerial lift did not wear a harness and lanyard attached to the basket when in the lift.
Recent events (1)
- — Z (S) $2000
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Metal Shed - One portable fire extinguisher was not mounted, another did not have the location labeled or identified and a third extinguisher was not readily accessible as material had accumulated in front of it.
Recent events (1)
- — Z (S) $1200
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: At the Facility - The employer did not conduct visual inspections of the portable fire extinguishers.
Recent events (1)
- — Z (S) $0
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Motor Room - The drive belt and pulley assembly on the air compressor was not guarded.
Recent events (1)
- — Z (S) $2000
More inspections in this industry (NAICS 423930)
OGDEN, UT—2026-07-10
TEAR A PART AUTO RECYCLING
GARNER, NC—2026-07-09
161490 - CAROLINA METAL RECYCLERS, LLC
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
HOLBROOK, NY—2026-07-01
ARROW SCRAP CORPORATION
DOVER, OH—2026-07-01
SPEEDIE AUTO SALVAGE
More inspections in ME
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06
SHAW'S SUPERMARKETS
GORHAM, ME—2026-07-02
TOWN OF GORHAM
FARMINGTON, ME—2026-07-02
MCTA GENERAL CONSTRUCTION CORP
FARMINGTON, ME—2026-07-02
JC HOME IMPROVEMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339112849.