2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: HITTLE ROOFING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HITTLE ROOFING INC. in 1425 NEWARK ROAD, ZANESVILLE, OH 43701 (NAICS 238160). OSHA activity number 339342727.

Watch Hittle Roofing INC. — free Get an email when a new federal OSHA severe-injury report for Hittle Roofing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HITTLE ROOFING INC.
Site address
1425 NEWARK ROAD
City
ZANESVILLE
State
OH
ZIP
43701
Mailing
3025 OLD FALLS ROAD, ZANESVILLE, OH 43701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.1051 A

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1428.00 Reduced
29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.    a.    On the top roof of the building  there was a ladder set up for access to the Nate Auditorium roof which had a break in elevation of 28 1/2 inches thereby exposing the employees to a 9 foot 6 inch fall hazard.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $1700

1926.1053 B15

Deleted Serious Gravity 1 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(15): Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.  a.    On the Zanesville site where roofing work was being performed, the portable ladders were not inspected by a competent person for defects, damage to the ladder thereby exposing employees to a struck-by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1020

1926.1053 B16

Other-than-serious 2 instances 7 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired.    a.    On the south side of the building, the ladder used to gain access to the upper floor was missing a rope to raise and lower the ladder thereby exposing employees to a struck-by hazard.     b.    On the east side of the 2nd floor where employees accessed the roof, the aluminum ladder was missing the rope to raise and lower the upper part of the ladder thereby exposing employees to a struck-by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1360

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339342727.