Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FORTITECH, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FORTITECH, INC. in 2105 TECHNOLOGY DRIVE, SCHENECTADY, NY 12308 (NAICS 325412). OSHA activity number 339393084.

Watch Fortitech, INC. — free Get an email when a new federal OSHA severe-injury report for Fortitech, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FORTITECH, INC.
Site address
2105 TECHNOLOGY DRIVE
City
SCHENECTADY
State
NY
ZIP
12308
Mailing
2105 TECHNOLOGY DRIVE, SCHENECTADY, NY 12308
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
220
Ownership type
A

5 citations on file for this inspection.

1910.146 K01 II

Serious Gravity 5 1 instance 90 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $4000.00
29 CFR 1910.146(k)(1)(ii): When designating rescue and emergency services pursuant to paragraph (d)(9), the employer did not evaluate the prospective rescuer's ability, in terms of proficiency with rescue-related tasks and equipment, to function appropriately while rescuing entrants from the particular space or types of spaces identified:  a)  Mixing Rooms - On and prior to September 5, 2013, the employer did not contact the permit required confined space rescue team or verify the team could respond during a permit required confined space entry (American Process Systems Cylindrical Plow Blender) involving mechanical exposure.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.147 C04 I

Serious Gravity 10 1 instance 90 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $3500.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  Mixing Room 580 #2 - On or about September 5, 2013, the employer did not have a specific energy control procedure for the control of hazardous energy for mixers including but not limited to, Mixer 580 #2 (American Process Systems Cylindrical Plow Blender).  Employees are exposed to moving parts while cleaning the mixing tanks and while scraping product out.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.147 D04 I

Serious Gravity 10 2 instances 90 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $3500.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    a)  Mixing Room 580 #2 - On or about September 5, 2013, authorized employees do not apply locks to the compressed air shut off handle prior to cleaning the blender (American Process Systems Cylindrical Plow Blender).  The air powers the seal at the discharge box.    b)  Mixing Room 580 #2 - On or about July 26, 2013, an authorized employee did not apply locks to the compressed air shut off handle or the electrical disconnect prior to opening and reaching in the discharge box door to clear product from the seal on the blender (American Process Systems Cylindrical Plow Blender).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.303 F01

Serious Gravity 5 1 instance 90 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $1250.00 Reduced
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:      a)  Mixing Rooms - Including 580 Mixer Room #2 - On and prior to September 5, 2013, the electrical disconnect for the 580 #2 Blender (American Process Systems Cylindrical Plow Blender) was not labeled.
Recent events (2)
  • — I (S) $1250
  • — Z (S) $5000

1910.1030 D04 II

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $2500.00 Reduced
29 CFR 1910.1030(d)(4)(ii): Equipment, environmental surfaces, or working surfaces were not cleaned and decontaminated after contact with blood or other potentially infectious materials:    a)  580 Mixer Room #2 - On or about July 25, 2013, the cleaning solutions used (Dubois Blue Foam Cleaner and Oakite Sanitizer 4) were not effective for bloodborne pathogens, such as but not limited to, Hepatitis B, Hepatitis C, HIV, and Tuberculosis.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

View FORTITECH, INC.'s full OSHA safety record →