MATTOON, WI —
OSHA Inspection: WISCONSIN VENEER & PLYWOOD, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WISCONSIN VENEER & PLYWOOD, INC. in 610 RAILROAD STREET, MATTOON, WI 54450 (NAICS 321211). OSHA activity number 339424152.
Where did this inspection happen?
- Establishment
- WISCONSIN VENEER & PLYWOOD, INC.
- Site address
- 610 RAILROAD STREET
- City
- MATTOON
- State
- WI
- ZIP
- 54450
- Mailing
- P.O. BOX 140, MATTOON, WI 54450
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321211
- Employees
- 129
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) On or about 9/30/2013, in the Southwest corner of the boiler room, storage on racks and below the fire extinguisher was not orderly, with insecure storage. This area was used as a passageway for the boiler room. b) On or about 9/26/2013, in the Hog room, saw dust was covering floors and equipment including a floor cover that was open. Additional wood scrap was on the floor outside of room by the barn cleaner. c) On or about 9/26/2013, saw dust and scrap were piled up in the aisle by black end hog. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $4000
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 9/30/2013, employees were performing lockout, and the procedures used were not audited on an annual basis. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) On or about 9/26/2013, the Splicer No. 2 cut off area was not fully guarded to prevent access during operation, such as when clearing jams. The approximately 24" guard door was not secured in place. b) On or about 9/26/2013, the Splicer No. 3 cut off area was not fully guarded to prevent access during operation, such as when clearing jams. c) On or about 9/26/2013, the Bunch clipper, 66"COE had an approximately 3" gap in the guard. The clipper knife was approximately 7" inside of that gap, (North side of machine). d) On or about 9/30/2013, the chipper in the saw mill was not guarded over the 23" x 19" opening. Pieces of wood were also being kicked back out of that opening. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $5000
1910.219 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) On or about 9/26/2013, in the aisle by black end hog, a rotating drive shaft was only partially guarded. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about 9/26/2013, the drive belt and pulley were not guarded for the barn cleaner in the hog room. Located approximately 6' off the ground. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) On or about 9/26/2013, the drive belt and pulley were not guarded for the barn cleaner in the hog room, located approximately 6' off the ground. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: a) On or about 9/26/2013, a chain and sprocket were not guarded for the barn cleaner in the hog room approximately 5 1/2' off the ground. b) On or about 9/26/2013, a chain and sprocket infeed drive were not guarded below the log deck. c) On or about 9/26/2013, a chain and sprocket drive for the 56" COL line feed conveyor drive were not guarded below the conveyor. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 9/30/2013, the grinder room air hose used for cleaning on a daily basis did not have a pressure reduction air wand end. The air pressure in the line was approximately 115 p.s.i. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about 9/26/2013, in the Maintenance shop, the POWER SYSTEMS Circulating Large Parts Washer did not have a label on it to identify the chemical contained or the hazards presented by the chemical, (Northwoods Natures Way II, Degreaser & Solvent). b) On or about 9/30/2013, in the Boiler room chemicals in drums and tanks did not have a label to identify the chemical contained or the hazards presented by the chemicals, (Corrosive boiler antifoam, Fremont 8826 oxygen scavenger). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1500
- — Z (S) $3000
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) On or about 9/26/2013, in the Maintenance shop, the POWER SYSTEMS, Circulating Large Parts Washer did not have a label on it to identify the chemical contained or the hazards presented by the chemical, (Northwoods Natures Way II, Degreaser & Solvent). b) On or about 9/30/2013, in the Boiler room, chemicals in drums and tanks did not have a label to identify the chemical contained or the hazards presented by the chemicals, (Corrosive boiler antifoam, Fremont 8826 oxygen scavenger). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: a) On or about 9/26/2013, the employer did not have a copy of the MSDS available on site for (KLEAN-STRIP) S-L-X Denatured Alcohol which was used to thin out putty. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at WISCONSIN VENEER & PLYWOOD, INC.
MATTOON, WI—2019-06-12 00:00:00
WISCONSIN VENEER & PLYWOOD, INC.
MATTOON, WI—2016-01-28 00:00:00
WISCONSIN VENEER & PLYWOOD, INC.
View WISCONSIN VENEER & PLYWOOD, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321211)
FANWOOD, NJ—2026-07-10
CLOSET FACTORY
COLFAX, NC—2026-06-09
161334 - BALTEK INC.
CRAIGSVILLE, WV—2026-05-29
COLUMBIA FOREST PRODUCTS, INC.
PIQUA, OH—2026-04-23
HARTZELL HARDWOODS
CAMDEN, TX—2026-03-24
GEORGIA PACIFIC WOOD PRODUCTS
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source