ERIE, PA —
OSHA Inspection: HORRIFYING PRODUCTIONS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HORRIFYING PRODUCTIONS, LLC in 1053 WEST 12TH STREET, ERIE, PA 16501 (NAICS 713990). OSHA activity number 339441115.
Where did this inspection happen?
- Establishment
- HORRIFYING PRODUCTIONS, LLC
- Site address
- 1053 WEST 12TH STREET
- City
- ERIE
- State
- PA
- ZIP
- 16501
- Mailing
- 11805 MORNING SHORES DRIVE, CONNEAUT LAKE, PA 16316
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 713990
- Employees
- 46
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 C
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc. A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, conveyer room, on or about October 25, 2013 and times prior thereto: Pit not guarded. Personnel exposed to a 7-feet fall hazard into the pit.
Recent events (3)
- — C (S) $2800
- — F (S) $700
- — Z (S) $2800
1910.36 G02
- Issued
- Abate by
- Penalty
- Initial $4200.00 · Current $1050.00 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, graveyard / cemetery, on or about October 25, 2013 and times prior thereto: Employees perform haunted house activities in an enclosed area with a wall height of 49-inches. The exit route from the enclosed area was 17.25 inches in width. B.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, graveyard / cemetery, on or about October 25, 2013 and times prior thereto: Employees performing haunted house activities in an enclosed area had a 21-inch wide path of travel from one side of the enclosed area to the other side of the enclosed area where the exit was located. C.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, box maze, on or about October 25, 2013 and times prior thereto: Employees escort guests through area haunted house, including, but not limited to, the box maze. The width clearance between the wall and the constructed box was 24-inches. D.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, barrel maze, on or about October 25, 2013 and times prior thereto: Employees escort guests through area haunted house, including, but not limited to, the barrel maze. The width clearances between the wall and the barrels were 24-inches. E.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, barrel maze, on or about October 25, 2013 and times prior thereto: Employees escort guests through area haunted house, including, but not limited to, the barrel maze. The width clearance between the walls and a metal post were 23.5-inches and 22-inches. F.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, hospital room, on or about October 25, 2013 and times prior thereto: Employees escort guests through area haunted house, including, but not limited to, the hospital room. The width clearance between the constructed walls was 27-inches.
Recent events (3)
- — C (S) $4200
- — F (S) $1050
- — Z (S) $4200
1910.36 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.36(g)(1): Ceiling of an exit route was not at least seven feet six inches. A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, graveyard / cemetery, on or about October 25, 2013 and times prior thereto: Employees perform haunted house activities in an enclosed area with a wall height of 49-inches. The exit route from the enclosed area is 45.5 inches in height. Employees have to crawl through the exit route.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1910.36 G04
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1910.36(g)(4): Objects that projected into the exit route reduced the width of the exit route to less than the minimum width requirements for exit routes: A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, second floor / stair tower #1, on or about October 25, 2013 and times prior thereto: Employees perform various haunted house activities, including, but not limited to, acting and escorting guests throughout the haunted house. A door way used for emergency egress from a haunted house room was swinging into the path of the south emergency exit corridor blocking its path of egress. Door swing reduced exit route width to less than 1-foot.
Recent events (3)
- — C (S) $2800
- — F (S) $700
- — Z (S) $2800
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Stairs or a ramp were not provided where the exit route was not substantially level. A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, conveyer room, on or about October 25, 2013 and times prior thereto: Employees perform haunted house activities in an enclosed area with a wall height of 49-inches. An exit route from the area was not provided, and would require the employees to jump over the 49-inches high wall for emergency egress.
Recent events (3)
- — C (S) $2800
- — F (S) $700
- — Z (S) $2800
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $525.00 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, on or about October 31, 2013 and times prior thereto: An employee provided with, and permitted to use portable fire extinguishers did not have fire extinguisher training.
Recent events (3)
- — C (S) $2100
- — F (S) $525
- — Z (S) $2100
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, stair tower near control room, on or about October 25, 2013 and times prior thereto: A Buckeye multi-purpose dry chemical fire extinguishers was setting on the floor.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $700.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, control room, on or about October 25, 2013 and times prior thereto: An electrical box containing live electrical wires that supplied power to equipment including, but not limited to, four 120V receptacle was not equipped with a cover plate. B.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, main entrance area, on or about October 25, 2013 and times prior thereto: An electrical junction box was not equipped with a coverplate. C.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, waiting area, on or about October 31, 2013 and times prior thereto: An electrical junction box was not equipped with a coverplate.
Recent events (3)
- — C (S) $2800
- — F (S) $700
- — Z (S) $2800
1910.303 B07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(7): Electrical equipment was not installed in a neat and workmanlike manner: A.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, main entrance area, on or about October 25, 2013 and times prior thereto: Electrical wiring splices were located outside of the junction box. B.) Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, outside control room, on or about October 31, 2013 and times prior thereto: Electrical wiring splices were located outside of the junction box.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Horrifying Productions, LLC dba Eeriebyss Factory of Terror, 1053 West 12th Street, Erie, PA 16501, control room, on or about October 25, 2013 and times prior thereto: Electrical breakers including, but not limited to, #11 and #14 were not labeled as to their purpose.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
More inspections at HORRIFYING PRODUCTIONS, LLC
ERIE, PA—2013-10-31 00:00:00
HORRIFYING PRODUCTIONS, LLC
ERIE, PA—2013-10-24 00:00:00
HORRIFYING PRODUCTIONS, LLC
View HORRIFYING PRODUCTIONS, LLC's full OSHA safety record →
More inspections in this industry (NAICS 713990)
GLENDALE, AZ—2026-07-10 00:00:00
CPX2026XTP177X0012 - TOPGOLF USA GLENDALE, LLC
LAWRENCEVILLE, IL—2026-07-04 00:00:00
AMERICAN PATRIOT PYRO INC
BALLWIN, MO—2026-06-24 00:00:00
THE RANGE - ST. LOUIS WEST
SACRAMENTO, CA—2026-06-24 00:00:00
K1 SPEED SACRAMENTO
RIVERSIDE, CA—2026-06-19 00:00:00
TIME ENTERPRISE, INC
More inspections in PA
COLUMBIA, PA—2026-07-17 00:00:00
FOX TAPPING INC.
COLUMBIA, PA—2026-07-17 00:00:00
COLUMBIA WATER CO
WILKES BARRE, PA—2026-07-17 00:00:00
NEW ENTERPRISE STONE & LIME CO., INC.
PHILADELPHIA, PA—2026-07-16 00:00:00
MUKHLEEN GERNAROS PIZZA LLC DBA GENARO'S PIZZERIA AND STEAKS
PHILADELPHIA, PA—2026-07-16 00:00:00
CENTER CITY CONSTRUCTION AND DEVELOPMENT, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339441115.