BRADFORD, PA —
OSHA Inspection: PRECISION FABRICATION & CONTROLS, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PRECISION FABRICATION & CONTROLS, INC in 195 CHESTNUT STREET P.O. BOX 331, BRADFORD, PA 16701 (NAICS 332439). OSHA activity number 339482713.
Where did this inspection happen?
- Establishment
- PRECISION FABRICATION & CONTROLS, INC
- Site address
- 195 CHESTNUT STREET P.O. BOX 331
- City
- BRADFORD
- State
- PA
- ZIP
- 16701
- Mailing
- 195 CHESTNUT STREET P.O. BOX 331, BRADFORD, PA 16701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332439
- Employees
- 6
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1440.00 · Current $0.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: A.) Precision Fabrication & Controls, Inc. - On or about 11/13/13, employees were exposed to crush and impact hazards form powered industrial trucks that were not equipped with proper safety equipment/operator restraint systems. Forklift (Komatso FG305; Serial #143881A) was not equipped with an operator restraint system (i.e. seat belt). Employees operated the forklift for activities that included, but were not limited to loading/unloading trucks.
Recent events (2)
- — I (S) $0
- — Z (S) $1440
1910.22 A02
- Issued
- Abate by
- Penalty
- Initial $1800.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean condition: A.) Precision Fabrication & Controls, Inc.; wood cutting building - On or about 11/13/13, the company had an accumulation of combustible wood dust on the floor. The condition created the potential for fire/ explosion hazards.
Recent events (2)
- — I (S) $1500
- — Z (S) $1800
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. A.) Precision Fabrication & Controls, Inc.; wood cutting building - On or about 11/13/13, the company had an accumulation of combustible wood dust on a heater, miter saw table, and on top of light fixtures. The condition created the potential for fire/explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A.) Precision Fabrication and Controls, Inc.; wood cutting building - On or about 11/13/13, a general, 'household type' pelonis heater was being utilized in the working environment. These heaters were not designed for industrial environments and were exposed to combustible wood dust.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $1440.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): A.) Precision Fabrication and Controls, Inc. - On or about 11/13/13, employees were operating forklifts without being trained by the employer. Employees operated forklifts that included but were not limited to, Komatso FG305 (Serial #143881A).
Recent events (2)
- — I (S) $1000
- — Z (S) $1440
1910.178 L04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(4)(i): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. A.) Precision Fabrication and Controls, Inc. - On or about 11/13/13, employees were operating forklifts without being evaluated by the employer every three (3) years. Employees operated forklifts that included, but were not limited to, Komatso FG305 (Serial #143881A).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 R04
- Issued
- Abate by
- Penalty
- Initial $1440.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of miter saw and table saw: A.) Precision Fabrication & Controls, Inc.; wood working building - On or about 11/13/13, the guard on the Delta shop master miter saw was missing for the saw blade.
Recent events (2)
- — I (S) $1000
- — Z (S) $1440
1910.213 D01
- Issued
- Abate by
- Penalty
- Initial $1440.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: A.) Precision Fabrication & Controls, Inc.; wood working building - On or about 11/13/13, the guard on the Ryobi table saw was missing for the saw blade.
Recent events (2)
- — I (O) $0
- — Z (S) $1440
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $1080.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: A.) Precision Fabrication and Controls Inc.; main building; south wall - On or about 11/13/13, the company was storing pieces of stainless steel sheet metal under and in front of a 480 volt electrical panel box.
Recent events (2)
- — I (S) $1000
- — Z (S) $1080
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: A.) Precision Fabrication and Controls Inc.; assembly area - On or about 11/13/13, an extension cord was daisy chained to another extension cord to power fluorescent lamps.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PRECISION FABRICATION & CONTROLS, INC
BRADFORD, PA—2013-11-13 00:00:00
PRECISION FABRICATION & CONTROLS, INC.
BRADFORD, PA—2012-02-28 00:00:00
PRECISION FABRICATION & CONTROLS, INC.
BRADFORD, PA—2006-01-31 00:00:00
PRECISION FABRICATION & CONTROLS, INC.
View PRECISION FABRICATION & CONTROLS, INC's full OSHA safety record →
More inspections in this industry (NAICS 332439)
OKOLONA, KY—2026-06-24
69249 - CONCO INC
GOODYEAR, AZ—2026-06-16
CPX2026XTP177X0009 - INSTITUTE OF GAS TECHNOLOGY DBA GTI ENERGY
WOOSTER, OH—2026-05-14
E-PAK MANUFACTURING, LLC.
CLEVELAND, OH—2026-05-11
MAUSER PACKAGING SOLUTIONS
PEOTONE, IL—2026-05-07
CLEVELAND STEEL CONTAINER CORPORATION
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339482713.