Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION FABRICATION & CONTROLS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRECISION FABRICATION & CONTROLS, INC in 195 CHESTNUT STREET P.O. BOX 331, BRADFORD, PA 16701 (NAICS 332439). OSHA activity number 339482713.

Watch Precision Fabrication & Controls, INC — free Get an email when a new federal OSHA severe-injury report for Precision Fabrication & Controls, INC is published. One employer, no account, unsubscribe in one click.
Site address
195 CHESTNUT STREET P.O. BOX 331
City
BRADFORD
State
PA
ZIP
16701
Mailing
195 CHESTNUT STREET P.O. BOX 331, BRADFORD, PA 16701
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332439
Employees
6
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:      A.)  Precision Fabrication & Controls, Inc. - On or about 11/13/13, employees were  exposed to crush and impact hazards form powered industrial trucks that were not equipped with proper safety equipment/operator restraint systems.  Forklift  (Komatso FG305; Serial #143881A) was not equipped with an operator restraint system (i.e. seat belt).  Employees operated the forklift for activities that included, but were not limited to loading/unloading trucks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1440

1910.22 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1500.00 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean condition:          A.)  Precision Fabrication & Controls, Inc.; wood cutting building - On or about 11/13/13, the company had an accumulation of combustible wood dust on the floor. The condition created the potential for fire/ explosion hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $1800

1910.22 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.   A.)  Precision Fabrication & Controls, Inc.; wood cutting building - On or about 11/13/13, the company had an accumulation of combustible wood dust on a heater, miter saw table, and on top of light fixtures. The condition created the potential for fire/explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   A.)  Precision Fabrication and Controls, Inc.; wood cutting building - On or about 11/13/13, a general, 'household type' pelonis heater was being utilized in the working environment.  These heaters were not designed for industrial environments and were exposed to combustible wood dust.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $1000.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):        A.)  Precision Fabrication and Controls, Inc. - On or about 11/13/13, employees were operating forklifts without being trained by the employer.   Employees operated forklifts that included but were not limited to, Komatso FG305 (Serial #143881A).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1440

1910.178 L04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(4)(i): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.   A.)  Precision Fabrication and Controls, Inc. - On or about 11/13/13, employees were operating forklifts without being evaluated by the employer every three (3) years.  Employees operated forklifts that included, but were not limited to, Komatso FG305 (Serial #143881A).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 R04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $1000.00 Reduced
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of miter saw and table saw:        A.)  Precision Fabrication & Controls, Inc.; wood working building - On or about 11/13/13, the guard on the Delta shop master miter saw was missing for the saw blade.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1440

1910.213 D01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1440.00 · Current $0.00 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:        A.)  Precision Fabrication & Controls, Inc.; wood working building - On or about 11/13/13, the guard on the Ryobi table saw was missing for the saw blade.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1440

1910.303 G01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1080.00 · Current $1000.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:      A.)  Precision Fabrication and Controls Inc.; main building; south wall - On or about 11/13/13, the company was storing pieces of stainless steel sheet metal under and in front of a 480 volt electrical panel box.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1080

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   A.)  Precision Fabrication and Controls Inc.; assembly area - On or about 11/13/13, an extension cord was daisy chained to another extension cord to power fluorescent lamps.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PRECISION FABRICATION & CONTROLS, INC's full OSHA safety record →