OSHA Inspection: POLAR TANK TRAILER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of POLAR TANK TRAILER in 4825 E. KEARNEY ST., SPRINGFIELD, MO 65803 (NAICS 332420). OSHA activity number 339496200.

Watch Polar Tank Trailer — free Get an email when a new federal OSHA severe-injury report for Polar Tank Trailer is published. One employer, no account, unsubscribe in one click.
Establishment
POLAR TANK TRAILER
Site address
4825 E. KEARNEY ST.
City
SPRINGFIELD
State
MO
ZIP
65803
Mailing
P.O. BOX 310, SPRINGFIELD, MO 65801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
315
Ownership type
A

7 citations on file for this inspection.

1910.22 D01

Serious Gravity 1 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  (a) Maintenance Fabrication:  Employees were exposed to overhead storage above employee work areas that did not have a load rating.  (b) Maintenance Office:  Employees were exposed to overhead storage above employee work areas that did not have a load rating.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.179 G01 V

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:  (a) Center Base Center Crane:  Employees were exposed to the 3 lower buttons on the pendant for the Center Base Center Crane that were not labelled for use with the Sheet Lifter.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.179 J03

Serious Gravity 5 15 instances 40 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  (a) Center Bay Cranes: Cranes, such as but not limited to, the Centerbay Buffing Jib # 2, Centerbay D10 Jib Boom, Centerbay D11 Jib Boom and Centerbay Jib #6 had not had an annual inspection since March 6, 2012.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $5100.00 · Current $3570.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Center Bay:  Employees were exposed to pinch points from the shear blade and hold downs as the AccurShear 12 foot shear was missing the rods that were part of the lower shear guard. The far right section of the shear was missing two metal rods that were part of the guard. On or about August 7, 2013 an employee broke two fingers when shearing a piece of metal with the lower portion of the guard absent.  (b) ACX Pipe and Trim:  Employees were exposed to the saw blade for the Makita 14 inch Chop Saw which did not have a lower guard to adjust to the material being cut.
Recent events (2)
  • — I (S) $3570
  • — Z (S) $5100

1910.303 G01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a) Maintenance Fabrication:  Employees were exposed to electrical hazards as there were metal parts being stored in front of the electrical shut off.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

1910.305 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) Floor Utility:  A knockout was missing in the O.T. (Overturn) floor utility area exposing employees to electrical hazards.  (b) Small Roll Area:  The Roller electrical panel box had an open knockout exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.305 G01 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $2380.00 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):  (a) Compressor Room:  Employees were exposed to electrical hazards as the electrical extension cord was run through two doorways to charge the Snorkel Lift outside the building.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $3400

View POLAR TANK TRAILER's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339496200.