Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HOOD INDUSTRIES

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of HOOD INDUSTRIES in 915 INDUSTRIAL PARK ROAD, WAYNESBORO, MS 39367 (NAICS 321113). OSHA activity number 339499881.

Watch Hood Industries — free Get an email when a new federal OSHA severe-injury report for Hood Industries is published. One employer, no account, unsubscribe in one click.
Establishment
HOOD INDUSTRIES
Site address
915 INDUSTRIAL PARK ROAD
City
WAYNESBORO
State
MS
ZIP
39367
Mailing
915 INDUSTRIAL PARK ROAD, WAYNESBORO, MS 39367
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
102
Ownership type
A

2 citations on file for this inspection.

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $0.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)    a) On or about November 14, 2013 an Oxygen and Acetylene cylinder was not separated by a noncombustible barrier to protect against fire or explosion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.305 G02 III

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $3600.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:(a)(LOCATION)(IDENTIFY EQUIPMENT AND CONDITION(S))(STATE HAZARD(S) TO EMPLOYEE(S)NOTE: KNOTS IN CORDS, WINDING WITH TAPE, SPECIAL FITTINGS OR OTHER APPROVED MEANS OF CONNECTION ARE ACCEPTABLE (NEC 40010) 1910    a) On or about November 14, 2013 flood light use to keep the air compressor from freezing was not connecting to prevent the elcetrical cord strain release breaking.   b) On or about Novemeber 14, 2013 electrical cord plugged into an elctrical outlet exposing live wiring because of broken strain release.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $3600

View HOOD INDUSTRIES's full OSHA safety record →