OSHA Inspection: HOPE ROOFING & RESTORATION, LLC.

Foreign inspection · Safety discipline

On , OSHA opened a foreign safety inspection of HOPE ROOFING & RESTORATION, LLC. in 7768 GUNSIGHT PASS, LITTLETON, CO 80127 (NAICS 238160). OSHA activity number 339505232.

Watch Hope Roofing & Restoration, LLC. — free Get an email when a new federal OSHA severe-injury report for Hope Roofing & Restoration, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
7768 GUNSIGHT PASS
City
LITTLETON
State
CO
ZIP
80127
Mailing
70 DAWN HEATH CIRCLE, LITTLETON, CO 80127
Inspection type
Foreign (L)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:       a) On or about November 14, 2013, Hope Roofing & Restoration, LLC., as the controlling employer, did not ensure that employees of Carin Construction,LLC., a subcontractor, were protected from falls in excess of 6 feet. Workers were exposed to fall hazards in excess of 9 feet while engaged in roofing activities on the roof of a residential building with no fall protection in place.               Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $400.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access:     a) On or about November 14, 2013, Hope Roofing & Restoration, LLC., as a controlling employer, did not ensure that portable ladders, used to access upper landing surfaces, extend at least 3 feet above the upper landing surface to which the ladders were used to gain access. Employees of Carin Construction,LLC.,a subcontractor, were observed using a ladder to access the roof of a residential building. Ladder did not extend at least 3 ft above the landing platform and was not tied to the roof edge.        Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").