OSHA Inspection: ALUMINUM EXTRUSIONS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALUMINUM EXTRUSIONS, INC. in 140 MATTHEWS DR., SENATOBIA, MS 38668 (NAICS 331316). OSHA activity number 339558397.

Watch Aluminum Extrusions, INC. — free Get an email when a new federal OSHA severe-injury report for Aluminum Extrusions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
140 MATTHEWS DR.
City
SENATOBIA
State
MS
ZIP
38668
Mailing
140 MATTHEWS DR., SENATOBIA, MS 38668
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331316
Employees
75
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     (a) Jobsite - On or about January 21, 2014 the annual periodic inspection of energy control procedures was not conducted on maintenance employees to assure the lockout procedures were being followed.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.179 J03

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1260.00 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  (a) Oven - On or about January 21, 2014 a complete inspection of the Caffey crane had not been performed.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    (a) Oven - On or about January 21, 2014 the electrical circuit breaker box by the oven was not labeled to indicate what each breaker controls.