OSHA Inspection: BEXAR ENVIRONMENTAL

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BEXAR ENVIRONMENTAL in 905 N ST. MARYS ST, SAN ANTONIO, TX 78209 (NAICS 562910). OSHA activity number 339560021.

Watch Bexar Environmental — free Get an email when a new federal OSHA severe-injury report for Bexar Environmental is published. One employer, no account, unsubscribe in one click.
Establishment
BEXAR ENVIRONMENTAL
Site address
905 N ST. MARYS ST
City
SAN ANTONIO
State
TX
ZIP
78209
Mailing
17788 IH 35 SOUTH, LYTLE, TX 78052
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
25
Ownership type
A

5 citations on file for this inspection.

1926.150 C01 VIII

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:       The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 23, 2014 and at times prior to, Bexar Environmental provided portable fire extinguishers to employees performing asbestos abatement and the fire extinguishers were not inspected since 2005 exposing employees to potential fire hazards.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.404 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:       The YMCA Building 905 N St Marys St San Antonio TX:  On or about January 23, 2014, flexible cords used on site were plugged into a 3 outlet 3 prong extension cord which was plugged into a 3 outlet temporary power GFCI exposing employees to electrical hazards in a potentially wet environment.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.1101 G01 II

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced

Hazardous substances 9020

29 CFR 1926.1101(g)(1)(ii): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of wet methods or wetting agents to control employee exposures during asbestos handling, mixing, removal, cutting, application and cleanup:       The YMCA Building, mechanical room:  On or about January 23, 2014, Bexar Environmental did not ensure the use of wet methods and no wetting agents like amended water were used during abatement of Class I thermal system insulation (TSI) inside of a regulated containment area exposing employees to airborne asbestos.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1101 O03 I D

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced

Hazardous substances 9020

29 CFR 1926.1101(o)(3)(i)(D): The competent person did not supervise all employee exposure monitoring required by 29 CFR 1926.1101(o) and ensure that it is conducted as required by 29 CFR 1926.1101(f):       The YMCA Building, mechanical room in the basement:  On or about January 23, 2014, Bexar Environmental's competent person did not ensure that exposure monitoring for excursion limits and 8 hour TWA during class I asbestos abatement of TSI were being conducted exposing employees to airborne asbestos.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.1101 O03 I B

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced

Hazardous substances 9020

29 CFR 1926.1101(o)(3)(i)(B): The competent person did not ensure (by on-site inspection) the integrity of the enclosure or containment:       The YMCA Building, old mechanical room in the basement:  On or about January 23, 2014, the Bexar Environmental competent person, an asbestos abatement certified supervisor, did not ensure the containment did not have breaches or holes where class I thermal system insulation (TSI) was being abated exposing employees of other employers to airborne asbestos.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View BEXAR ENVIRONMENTAL's full OSHA safety record →