SAN ANTONIO, TX —
OSHA Inspection: BEXAR ENVIRONMENTAL
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BEXAR ENVIRONMENTAL in 905 N ST. MARYS ST, SAN ANTONIO, TX 78209 (NAICS 562910). OSHA activity number 339560021.
Where did this inspection happen?
- Establishment
- BEXAR ENVIRONMENTAL
- Site address
- 905 N ST. MARYS ST
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78209
- Mailing
- 17788 IH 35 SOUTH, LYTLE, TX 78052
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 25
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.150 C01 VIII
- Issued
- Penalty
- Initial $1600.00 · Current $960.00 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: The YMCA Building 905 N St Marys St San Antonio TX: On or about January 23, 2014 and at times prior to, Bexar Environmental provided portable fire extinguishers to employees performing asbestos abatement and the fire extinguishers were not inspected since 2005 exposing employees to potential fire hazards.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.404 B01 I
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: The YMCA Building 905 N St Marys St San Antonio TX: On or about January 23, 2014, flexible cords used on site were plugged into a 3 outlet 3 prong extension cord which was plugged into a 3 outlet temporary power GFCI exposing employees to electrical hazards in a potentially wet environment.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1101 G01 II
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(g)(1)(ii): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of wet methods or wetting agents to control employee exposures during asbestos handling, mixing, removal, cutting, application and cleanup: The YMCA Building, mechanical room: On or about January 23, 2014, Bexar Environmental did not ensure the use of wet methods and no wetting agents like amended water were used during abatement of Class I thermal system insulation (TSI) inside of a regulated containment area exposing employees to airborne asbestos.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1101 O03 I D
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(o)(3)(i)(D): The competent person did not supervise all employee exposure monitoring required by 29 CFR 1926.1101(o) and ensure that it is conducted as required by 29 CFR 1926.1101(f): The YMCA Building, mechanical room in the basement: On or about January 23, 2014, Bexar Environmental's competent person did not ensure that exposure monitoring for excursion limits and 8 hour TWA during class I asbestos abatement of TSI were being conducted exposing employees to airborne asbestos.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.1101 O03 I B
- Issued
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
9020
General-duty citation text
29 CFR 1926.1101(o)(3)(i)(B): The competent person did not ensure (by on-site inspection) the integrity of the enclosure or containment: The YMCA Building, old mechanical room in the basement: On or about January 23, 2014, the Bexar Environmental competent person, an asbestos abatement certified supervisor, did not ensure the containment did not have breaches or holes where class I thermal system insulation (TSI) was being abated exposing employees of other employers to airborne asbestos.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at BEXAR ENVIRONMENTAL
SAN ANTONIO, TX—2023-10-12 00:00:00
BEXAR ENVIRONMENTAL
View BEXAR ENVIRONMENTAL's full OSHA safety record →
More inspections in this industry (NAICS 562910)
DEER PARK, TX—2026-07-07
HPC INDUSTRIAL SERVICES, LLC
REDMOND, OR—2026-07-02
317744683 - ALPINE ABATEMENT ASSOCIATES INC
FISHER, IL—2026-07-02
ECO WASH LLC
BEND, OR—2026-06-30
317744684 - ALPINE ABATEMENT ASSOCIATES INC
MILL VALLEY, CA—2026-06-30
AXELSON BUILDERS INC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source