Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHESAPEAKE PLUMBING AND HEATING INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHESAPEAKE PLUMBING AND HEATING INC. in 302 PLANTATION DR, SEAFORD, DE 19973 (NAICS 237110). OSHA activity number 339580227.

Watch Chesapeake Plumbing AND Heating INC. — free Get an email when a new federal OSHA severe-injury report for Chesapeake Plumbing AND Heating INC. is published. One employer, no account, unsubscribe in one click.
Site address
302 PLANTATION DR
City
SEAFORD
State
DE
ZIP
19973
Mailing
34913 DELAWARE AVE., FRANKFORD, DE 19945
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3430.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i).    Jobsite: 302 Plantation Drive, Seaford, DE- Employee was buried inside a trench while making a residential connection to the main sewer line.  The employee was working inside a excavation approximately 40 feet long, 4 feet wide, and  the deepest part was approximately 6 feet deep with soil classified as type B. Observed on or about 2/7/2014.    Abatement Note:  Ensure protective system is provided such as sloping, benching, appropriate for soil type, or a trench box ior other type of protective system is used prior to authorizing an employee inside a trench 5 feet deep or greater or a trench under 5 feet deep with adverse condition and a potential for cave in.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  Jobsite:302 Plantation Drive, Seaford, DE- Employee was buried inside a trench while making a residential connection to the main sewer line.  The employee was working inside a excavation which was between 3 and 6 feet deep, approximately, without a ladder as means of egress.  Abatement note:  Ensusre to place a ladder or other means of egress at excavations that are 4 ft or more ind depth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  Jobsite:302 Plantation Drive, Seaford, DE- Employee was buried inside a trench while making a residential connection to the main sewer line.  The employee was working inside a excavation approximately 40 feet long, 4 feet wide and between 3 and 6 feet deep. The spoil pile was between 0 and 5 inches from the edge of the excavation.  Abatement Note:  Ensure excavated material is placed no closer than 2 feet from the edge of the excavation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3430.00 Reduced
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:    Jobsite:302 Plantation Drive, Seaford, DE- Employee was working inside an excavation approximately 6 feet deep. The excavation was not inspected by a competent person.    Abatement Note:  Ensure personnel conducting inspections of the excavations are competent in recognizing any evidence of situation that could result in cave-in, indications of failure of protective system, hazardous atmospheres or other hazardous conditions.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1926.100 A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  Jobsite:302 Plantation Drive, Seaford, DE- Employee was buried inside a trench while making a residential connection to the main sewer line.  The employee was working inside a excavation at 6 feet deep, approximately, without a hard hat. The spoil pile was within a foot from the edge of the excavation when it caved in.  In or about 2/7/14.  Abatement note:  Ensure employees wear a hard hat when working in areas where there is possible danger of head injury from impact.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View CHESAPEAKE PLUMBING AND HEATING INC.'s full OSHA safety record →