MIAMI, FL —
OSHA Inspection: CHEROKEE PUMPING OF FLORIDA LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHEROKEE PUMPING OF FLORIDA LLC in 3760 BIRD RD, MIAMI, FL 33146 (NAICS 238110). OSHA activity number 339597338.
Where did this inspection happen?
- Establishment
- CHEROKEE PUMPING OF FLORIDA LLC
- Site address
- 3760 BIRD RD
- City
- MIAMI
- State
- FL
- ZIP
- 33146
- Mailing
- 6511 NOVA DRIVE #285, DAVIE, FL 33317
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about February 21, 2014, at the above address jobsite, the employer did not provide training to a concrete boom pump truck operator who was exposed to hazards such as but not limited to electrical shock from overhead power lines of 138 kV.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.600 A06 II
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.600(a)(6)(ii): For lines rated over 50 kV, minimum clearance between the lines and any part of the crane or load were not 10 feet plus 0.4 inch for each 1 kV over 50 kV, or twice the length of the line insulator, but never less than 10 feet: On or about February 21, 2014, at the above address jobsite, the employer had placed a concrete boom pump truck at less than the required 45.2 ft from the overhead 138kV power lines.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections at CHEROKEE PUMPING OF FLORIDA LLC
MIAMI, FL—2016-03-14 00:00:00
CHEROKEE PUMPING OF FLORIDA, LLC
View CHEROKEE PUMPING OF FLORIDA LLC's full OSHA safety record →
More inspections in this industry (NAICS 238110)
FREELAND, WA—2026-07-10
WA317992031 - NORTH RIVER CONCRETE PUMPING LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
WEBSTER, TX—2026-07-09
ZITRO CONCRETE CONSTRUCTION LLC
CHICAGO, IL—2026-07-09
GOEBEL FORMING, LLC
SAN ANTONIO, TX—2026-07-08
URBAN CONCRETE CONTRACTORS LTD
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339597338.