Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PREMIER AVIATION OVERHAUL CENTER, LTD

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PREMIER AVIATION OVERHAUL CENTER, LTD in 394 HANGAR ROAD, ROME, NY 13441 (NAICS 488190). OSHA activity number 339602369.

Watch Premier Aviation Overhaul Center, LTD — free Get an email when a new federal OSHA severe-injury report for Premier Aviation Overhaul Center, LTD is published. One employer, no account, unsubscribe in one click.
Site address
394 HANGAR ROAD
City
ROME
State
NY
ZIP
13441
Mailing
394 HANGAR ROAD, ROME, NY 13441
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
135
Ownership type
A

8 citations on file for this inspection.

1910.95 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1755.00 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:        a) At the facility, on or about 6/11/14: An employee working in Paint Hangar/Bay 6 performing sanding to remove old coatings from an aircraft, was exposed to continuous noise at a level of 106.3% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 106.3% is approximately 90.4 dBA calculated as the 8 hour time weighted sound pressure level.  Sampling was conducted for 311 minutes.  A zero increment was included for the remaining 169 minutes of the workday.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1755
  • — Z (S) $2700

1910.134 D01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2955.00 Reduced
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:        a) At the facility, on or about, 6/11/14: Employees were exposed to levels of hexavalent chromium above the OSHA permissible exposure limit during sanding of old coatings off aircrafts and spraying of Sherwin Williams High Solid Corrosion Resistant Epoxy Primer onto aircrafts. Employees wore respirators equipped with organic vapor cartridges, not rated for particulate exposure.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $2955
  • — Z (S) $4500

1910.1026 C

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1026(c): Employees were exposed to an airborne concentration of chromium (VI) which exceeded 5 micrograms per cubic meter of air, as an 8-hour time-weighted average:      a) In the Paint Hangar/Bay 6, on or about 6/11/14: An employee who performed manual sanding on an aircraft to remove old coatings was exposed to airborne concentrations of Hexavalent Chromium which exceeded the Permissible Exposure Limit. OSHA air sampling showed an employee exposed to Hexavalent Chromium at an 8 hour time weighted average of 8 micrograms per cubic meter of air, 1.6 times the OSHA Permissible Exposure Limit. Sampling was performed for a period of 315 minutes. Zero exposure was calculated for the 165 minutes not sampled.       b) In the Paint Hangar/Bay 6, on or about 6/26/14: An employee who performed spraying of Sherwin Williams High Solid Corrosion Resistant Epoxy Primer onto an aircraft was exposed to airborne concentrations of Hexavalent Chromium which exceeded the Permissible Exposure Limit. OSHA air sampling showed an employee exposed to Hexavalent Chromium at an 8 hour time weighted average of 133.9 micrograms per cubic meter of air, 26.78 times the OSHA Permissible Exposure Limit. Sampling was performed for a period of 61 minutes. Zero exposure was calculated for the 419 minutes not sampled.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 D01

Serious Gravity 5 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):    a) In the Paint Hangar/Bay 6, on or about 2/26/14: Where employees performed sanding to remove old coatings from aircrafts, the employer did not determine employees exposure to Hexavalent Chromium. OSHA performed air sampling and results showed an employee exposed to Hexavalent Chromium at an 8 hour time weighted average of 8 micrograms per cubic meter of air.    b) In the Paint Hangar/Bay 6, on or about 2/26/14: Where employees performed spraying of Sherwin Williams High Solid Corrosion Resistant Epoxy Primer onto aircrafts, the employer did not determine employee exposure to Hexavalent Chromium. OSHA performed air sampling and results showed an employee exposed to Hexavalent Chromium at an 8 hour time weighted average of 133.9 milligrams per cubic meter of air.    c) In the Paint Hangar/Bay 6, on or about 3/14/14: Where employees used a squeegee to remove old coatings after the application of chemical stripper, the employer did not determine employee to hexavalent chromium.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 F01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1026(f)(1)(ii): Painting of aircraft or large aircraft parts was performed; however, the employer did not use feasible engineering and work practice controls to reduce and maintain employee exposures to chromium (VI) to or below 25 micrograms per cubic meter of air:   a) In the Paint Hangar/Bay 6, on or about 6/26/14: Employees sprayed Sherwin Williams High Solid Corrosion Resistant Epoxy Primer on aircrafts. OSHA air sampling showed an employee exposed to an 8 hour time weighted average of hexavalent chromium at 133.9 micrograms per cubic meter of air. The employer did not implement engineering or work practice controls to reduce employee exposure levels below 25 micrograms per cubic meter of air.    ABATEMENT WILL BE MULTI-STEP AS FOLLOWS:   Step 1: Effective respiratory protection which complies with 29 CFR 1910.134 to include fit testing, medical evaluations, and training shall be provided and used by exposed employee(s) as an interim protective measure until feasible engineering and/or administrative controls can be implemented, or whenever such controls fail to reduce employee exposure to within permissible exposure limits: (30 days)   Step 2: Submit to the Area Director a written detailed plan of abatement outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposure to hazardous substances as referenced in this citation. This plan shall include, at a minimum, target dates for the following actions which must be consistent with the abatement dates required by this citation: (60 days)   (1) Evaluation of engineering/administrative control options. Options include but are not limited to placing a cover over the opening which powders are poured into to reduce the amount of particulate which becomes airborne, or implementing local ventilation at the point of operation to capture airborne particulate which is generated during pouring of powders. (2) Evaluation to be conducted by a qualified person such as a certified industrial hygienist and/or licensed mechanical professional engineer. (3) Selection of optimum control methods and completion of design.  (4) Procurement, installation and operation of selected control measures.  (5) Testing and acceptance or modification/redesign of control measures.   Step 3: Abatement shall have been completed by the implementation of feasible, engineering and/or administrative controls upon verification of their effectiveness in achieving compliance. (180 days)
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 E01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $0.00 Reduced
29 CFR 1910.1026(e)(1): The employer did not establish a regulated area wherever an employee's exposure to airborne concentrations of chromium (VI) was, or could reasonably be expected to be, in excess of the permissible exposure limit:      a) In the Paint Hangar/Bay 6, on or about 6/11/14: The employer did not establish a regulated area where air sampling performed by OSHA showed an employee sanding old coatings off an aircraft exposed to an 8 hour time weighted average of Hexavalent Chromium at 8 micrograms per cubic meter of air, exceeding the permissible exposure limit of 5 micrograms per cubic meter.     b) In the Paint Hangar/Bay 6, on or about 6/26/14: The employer did not establish a regulated area where air sampling performed by OSHA showed an employee spraying Sherwin Williams High Solid Corrosion Resistant Epoxy Primer exposed to an 8 hour time weighed average of Hexavalent Chromium at 133.9 micrograms per cubic meter of air, exceeding the permissible exposure limit of 5 micrograms per cubic meter.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2700

1910.1026 K01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $3690.00 Reduced
29 CFR 1910.1026(k)(1)(i): The employer did not make medical surveillance for chromium (VI) exposures available at no cost to the employees, and/or at a reasonable time and place:      a) At the facility, on or about 6/11/14: The employer did not make medical surveillance for hexavalent chromium available to employees who may be exposed to levels exceeding the Permissible Exposure Limit during operations including sanding to remove old coatings off aircrafts, and spraying of primer onto aircrafts. OSHA air sampling showed employees exposed to 8 hour time weighted averages of Hexavalent Chromium at 8 ug/m3 of air during sanding, 133.9 ug/m3 of air during spraying of primer.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $3690
  • — Z (S) $4500

1910.1026 L02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $0.00 Reduced
29 CFR 1910.1026(l)(2)(i): Prior to initial job assignment to an area where employees were subject to chromium (VI)exposure, the employer did not ensure that each employee can demonstrate knowledge in the content of this section, and the purpose and description of the medical surveillance program required by paragraph (k) of this section.        a) At the facility, on or about 2/26/14: The employer did not ensure employees who performed sanding to remove old coatings, spraying of primer, and cleanup of old coatings after application of chemical stripper could demonstrate knowledge on the contents of the OSHA hexavalent chromium standard and the purpose and description of the medical surveillance program.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2700

View PREMIER AVIATION OVERHAUL CENTER, LTD's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339602369.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.