Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUNVILLE TRUCKING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GUNVILLE TRUCKING, INC. in 1050 WASHINGTON, NIAGARA, WI 54151 (NAICS 484121). OSHA activity number 339639510.

Watch Gunville Trucking, INC. — free Get an email when a new federal OSHA severe-injury report for Gunville Trucking, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1050 WASHINGTON
City
NIAGARA
State
WI
ZIP
54151
Mailing
PO BOX 77, NIAGARA, WI 54151
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484121
Employees
110
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $4950.00
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that, employees were exposed to struck by hazards from falling loads:  On and before 3/19/14, employees of Gunville Trucking Inc. were exposed to struck by hazards while handling loads with an overhead crane and a wall mounted jib crane, both of which were not equipped with latches on the hoist hooks to prevent inadvertent disconnection of the load from the hooks.
Recent events (3)
  • — F (S) $4950
  • — C (S) $4950
  • — Z (S) $4950

1910.179 B05

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $4950.00
29 CFR 1910.179(b)(5): The rated load of crane(s) was not plainly marked on each side of the crane:  On and before 3/19/14, the column mounted jib crane was not marked with plainly marked load rating visible from the floor.
Recent events (3)
  • — F (S) $4950
  • — C (S) $4950
  • — Z (S) $4950

1910.179 J02

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections:  On and before 3/19/14, cranes in use in the diesel shop had not been inspected in order to identify deficiencies including:   A) Electrical hazards, load rating markings, and missing load hook latch on the jib crane.  B) Missing latch and deformation in the load hook on the overhead crane.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $6930.00 · Current $6930.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  On 3/19/14, the work rest on a Baldor bench grinder had a gap of approximately 1/2" between the tool rest and the grinding wheel.
Recent events (3)
  • — F (S) $6930
  • — C (S) $6930
  • — Z (S) $6930

1910.215 B09

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   On 3/19/14, the tongue guard on the Baldor bench grinder was not adjusted to within 1/4" of the perimeter of the wheel.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $4950.00 · Current $4950.00
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  On 3/19/14, a conduit carrying a 220 AC volt electrical circuit located in the trailer shop was broken and pulled apart with the conductors exposed.
Recent events (3)
  • — F (S) $4950
  • — C (S) $4950
  • — Z (S) $4950

1910.303 B02

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On 3/19/14, an extension cord used to power a portable welder was plugged into an energized 220 AC volt metal receptacle junction box that was not wired with permanent wiring and secured in a permanent location as intended by listing and labeling to be used only for permanent installation.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   On 3/19/14, the power cord supplying the Milwaukee chain hoist in the diesel shop was missing the strain relief and bushing where the cord entered the housing of the hoist which put stress on the conductors and had pulled the ground wire loose from the electrical equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $3960.00 · Current $3960.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On and before 3/19/14, portable tools and extension cords had not been inspected before use to identify defects or possible damage.
Recent events (3)
  • — F (S) $3960
  • — C (S) $3960
  • — Z (S) $3960

1910.334 A02 II

Serious Gravity 5 3 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  On 3/19/14, electrical equipment, to include extension cords, trouble lights and a chain hoist, were in use when defects and improper repairs were plainly visible.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View GUNVILLE TRUCKING, INC.'s full OSHA safety record →