OMAHA, NE —
OSHA Inspection: CHIEF SCHOOL BUS SERVICE INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CHIEF SCHOOL BUS SERVICE INC. in 3111 S 67TH ST, OMAHA, NE 68106 (NAICS 485410). OSHA activity number 339653164.
Where did this inspection happen?
- Establishment
- CHIEF SCHOOL BUS SERVICE INC.
- Site address
- 3111 S 67TH ST
- City
- OMAHA
- State
- NE
- ZIP
- 68106
- Mailing
- 3111 S 67TH ST, OMAHA, NE 68106
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 485410
- Employees
- 140
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.38 B
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review in case of fire or other emergency. A written emergency action plan for fire or other emergency was not available upon agency request.
Recent events (3)
- — J (S) $0
- — C (S) $4500
- — Z (S) $4500
1910.141 C01 I
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in accordance with TABLE J-1 of this Section. Employer did not provide the required number of toilets/water closets to comply with Table J-1. Only two (2) toilets were available for over 100 driver and mechanic employees. A minimum of five (5) toilets are required for 81 to 110 employees and a minimum of six (6) toilets are required for 111 to 150 employees.
Recent events (3)
- — J (O) $0
- — C (S) $3600
- — Z (S) $3600
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $3825.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. An energy control/lockout-tagout program was not available upon agency request for maintenance/servicing on equipment including, but not limited to buses, vans, and compressors.
Recent events (3)
- — J (S) $3825
- — C (S) $4500
- — Z (S) $4500
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $3825.00 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. Circuit breakers and fuses including, but not limited to the panels located in the main floor restroom, were not labeled to indicate their purpose.
Recent events (3)
- — J (S) $3825
- — C (S) $4500
- — Z (S) $4500
1910.303 G01 I A
- Issued
- Abate by
- Penalty
- Initial $4500.00 · Current $3825.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910. Bay 3 Garage Area: A mounted compressor and stored equipment blocked access to multiple electrical panels and eliminated any available working space.
Recent events (3)
- — J (S) $3825
- — C (S) $4500
- — Z (S) $4500
1910.305 G01 IV
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $3060.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) in the following instances: A) Flexible cords were used as a substitute for fixed wiring and attached to building surfaces in areas including, but not limited to fluorescent lighting in the maintenance shop and east driver break room. B) Flexible cords were run through holes in walls in areas including, but not limited to the timeclock wiring by the east exit door.
Recent events (3)
- — J (S) $3060
- — C (S) $3600
- — Z (S) $3600
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $3600.00 · Current $3060.00 Reduced
13712020
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii). A written chemical hazard communications program was not available upon agency request. Employee(s) are exposed to chemicals including, but not limited to brake cleaner and starting fluid.
Recent events (3)
- — J (S) $3060
- — C (S) $3600
- — Z (S) $3600
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
13712020
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Employee(s) had not received effective chemical hazard communication training. Employee(s) are exposed to chemicals including, but not limited to brake cleaner and starting fluid.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 485410)
WOODBURY HEIGHTS, NJ—2026-07-09
GATEWAY REGIONAL SCHOOL DISTRICT BUS GARAGE
DEPTFORD, NJ—2026-07-07
TOWNSHIP OF DEPTFORD SCHOOL DISTRICT
WOODBURY HEIGHTS, NJ—2026-07-01
GATEWAY REGIONAL HIGH SCHOOL DISTRICT
ROSEDALE, MD—2026-06-29
DURHAM SCHOOL SERVICES, LIMITED PARTNERSHIP
MEDFORD, NJ—2026-06-29
LENAPE REGIONAL HIGH SCHOOL DISTRICT
More inspections in NE
CRETE, NE—2026-07-15
SMITHFIELD FOODS
OMAHA, NE—2026-07-14
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339653164.