DIAMOND, OH —
OSHA Inspection: NUVERRA ENVIRONMENTAL SOLUTIONS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NUVERRA ENVIRONMENTAL SOLUTIONS in 4317 STATE ROUTE 225, DIAMOND, OH 44412 (NAICS 213112). OSHA activity number 339799306.
Where did this inspection happen?
- Establishment
- NUVERRA ENVIRONMENTAL SOLUTIONS
- Site address
- 4317 STATE ROUTE 225
- City
- DIAMOND
- State
- OH
- ZIP
- 44412
- Mailing
- PO BOX 187, DIAMOND, OH 44412
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 55
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.106 B02 VII A
- Issued
- Abate by
- Penalty
- Initial $3400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.106(b)(2)(vii)(a): Area(s) surrounding tank(s) containing flammable liquids were not provided with adequate drainage or dikes: The diesel fuel tank located near the DEF storage shed had no dike or drain to contain spills or leaks from the tank.
Recent events (2)
- — I (S) $0
- — Z (S) $3400
1910.303 B02
- Issued
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In the DEF storage shed, the DEF pump, an overhead light and a heater, were plugged into a multiple outlet power strip. These devices are not approved for an industrial location.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
1910.305 G01 II
- Issued
- Penalty
- Initial $2550.00 · Current $1785.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(ii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: An extension cord was used as a substitute for fixed wiring and was run through a hole in the shed wall: In the DEF storage shed, the DEF pump, an overhead light and a heater, were powered by an extension cord, which ran across the lawn from the storage shed to the office building.
Recent events (2)
- — I (S) $1785
- — Z (S) $2550
More inspections at NUVERRA ENVIRONMENTAL SOLUTIONS
LORE CITY, OH—2022-11-28 00:00:00
NUVERRA ENVIRONMENTAL SOLUTIONS
View NUVERRA ENVIRONMENTAL SOLUTIONS's full OSHA safety record →
More inspections in this industry (NAICS 213112)
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
GARDEN CITY, TX—2026-06-17
EBENEZER COMPANIES LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339799306.