PLATTSBURGH, NY —
OSHA Inspection: FORT EDWARD EXPRESS CO. INC./4 STAR BULK TRANSPORT
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FORT EDWARD EXPRESS CO. INC./4 STAR BULK TRANSPORT in 4687 ROUTE 9, PLATTSBURGH, NY 12901 (NAICS 484121). OSHA activity number 339813107.
Where did this inspection happen?
- Establishment
- FORT EDWARD EXPRESS CO. INC./4 STAR BULK TRANSPORT
- Site address
- 4687 ROUTE 9
- City
- PLATTSBURGH
- State
- NY
- ZIP
- 12901
- Mailing
- 4687 ROUTE 9, PLATTSBURGH, NY 12901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $2295.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) Main shop area; south wall, on or about 6/18/14: Where employees use corrosive materials such as, but not limited to Aluminum Cleaner, the wall-mounted emergency eyewash station (rinse bottle) did not meet the requirements of ANSI Z358.1.
Recent events (2)
- — I (S) $2295
- — Z (S) $3060
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $2295.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. (a) Main shop area, North wall: One oxygen (oxidizer) and two acetylene (flammable) cylinders were stored without separation of 20 feet or use of a 5 foot high fire wall.
Recent events (2)
- — I (S) $2295
- — Z (S) $3060
1910.305 J01 IV
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $1710.00 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(iv): Fixtures installed in wet or damp locations were not approved for the purpose and were not so constructed or installed that water could not enter or accumulate in wireways, lampholders, or other electrical parts: (a) West side of main shop area, on or prior to 6/18/14: Ceiling lighting and fixtures were exposed to wet/damp conditions caused by a roof leak; lighting and fixtures were not approved for use in wet locations.
Recent events (2)
- — I (S) $1710
- — Z (S) $2295
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) Main shop area, on or about 6/18/14: Several portable fire extinguishers were not mounted in that mounting brackets were broken and/or missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor: (a) South wall of main shop, on or about 6/18/14: Horizontal run of metallic conduit enclosing 120v single-phase wiring was not continuous. (b) Main shop, interior column closest to North side: Vertical run of metallic conduit enclosing 120v single-phase wiring was not continuous near ceiling and at a box containing a single pole toggle switch.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords were attached to building surfaces: a) South side of main shop, on or about 6/18/14: A flexible cord was zip-tied to the partition wall above a door labeled "Andy's Room".
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FORT EDWARD EXPRESS CO. INC./4 STAR BULK TRANSPORT
PLATTSBURGH, NY—2014-12-29 00:00:00
FORT EDWARD EXPRESS CO. INC./4 STAR BULK TRANSPORT
View FORT EDWARD EXPRESS CO. INC./4 STAR BULK TRANSPORT's full OSHA safety record →
More inspections in this industry (NAICS 484121)
YUMA, AZ—2026-07-07
RFX2026XMG193X0063 - HOGAN DEDICATED SERVICES LLC DBA HOGAN TRANSPORTS
OAKLAND, CA—2026-07-07
ROEHL TRANSPORT, INC.
CHARLOTTE, NC—2026-07-06
161495 - FATHER - SONS LLC
SMYRNA, TN—2026-07-06
SILK WAY TRANSPORT, INC
KELLER, TX—2026-06-29
SHOW 1 LOGISTICS
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339813107.