2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: GUARANTEE ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUARANTEE ROOFING in 1220 SO. 200TH AVE, OMAHA, NE 68130 (NAICS 238160). OSHA activity number 339815144.

Watch Guarantee Roofing — free Get an email when a new federal OSHA severe-injury report for Guarantee Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
GUARANTEE ROOFING
Site address
1220 SO. 200TH AVE
City
OMAHA
State
NE
ZIP
68130
Mailing
1111 SURREY ROAD, PAPILLION, NE 68046
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.403 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose.  Jobsite: At or near 1220 So. 200th Ave, Omaha, NE - A metal 4-plex outlet box was not used as listed, was sitting on the ground and used to power an air compressor.
Recent events (1)
  • — Z (S) $1600

1926.405 G02 IV

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.   Jobsite: 1220 So. 200th Ave, Omaha, NE - Flexible electrical cords  used to power an outlet box and a Rolair compressor, were pulling away from their plug fittings and not provided proper strain relief.
Recent events (1)
  • — Z (S) $1600

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).  June 19, 2014 - At or near 1220 So. 200th Ave, Omaha, NE - Employee(s) were engaged in residential roofing activity, at ground to leading edge heights exceeding 11 feet, without any form of fall protection.
Recent events (1)
  • — Z (S) $2800

1926.503 A01

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  June 19, 2014 - At or near 1220 So. 200th Ave, Omaha, NE - Employee(s) were engaged in residential roofing activity, at ground to leading edge heights exceeding 11 feet, without being provided the fall protection training required by the standard.