Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRAVELCENTERS OF AMERICA LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRAVELCENTERS OF AMERICA LLC in 125 NEELEYTOWN ROAD, MONTGOMERY, NY 12549 (NAICS 447110). OSHA activity number 339817801.

Watch Travelcenters OF America LLC — free Get an email when a new federal OSHA severe-injury report for Travelcenters OF America LLC is published. One employer, no account, unsubscribe in one click.
Site address
125 NEELEYTOWN ROAD
City
MONTGOMERY
State
NY
ZIP
12549
Mailing
125 NEELEYTOWN ROAD, MONTGOMERY, NY 12549
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
447110
Employees
22000
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $8400.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  On or about May 9, 2014 at 125 Neeleytown Road, Montgomery NY, in the truck repair facility, a procedure to control potentially hazardous energy was not available or developed for servicing the Graco grease pump.  Employees were exposed to a amputation hazard when the compressed air in the grease pump was not correctly neutralized prior to working on the pump due to the lack of the procedure.
Recent events (2)
  • — I (S) $8400
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    a)  On or about May 9, 2014 at 125 Neeleytown Road, Montogmery, NY 12549 employees were not trained on a specific procedure to neutralize the stored energy in the Graco grease pump.  The specific procedure to control the residual energy (compressed air) in the grease pump was not developed and accordingly the training was needed on a specific procedure yet to be developed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a)  On or about June 20, 2014 at 125 Neeleytown Road, Montgomery, NY 12549 a fire extinguisher was not mounted and identified by a sign but was sitting on the floor of bay 1 near the wall closest to the service desk.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View TRAVELCENTERS OF AMERICA LLC's full OSHA safety record →