OSHA Inspection: FORMOSA PLASTICS CORPORATION, TEXAS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FORMOSA PLASTICS CORPORATION, TEXAS in 201 FORMOSA DR, POINT COMFORT, TX 77978 (NAICS 325211). OSHA activity number 339852964.

Watch Formosa Plastics Corporation, Texas — free Get an email when a new federal OSHA severe-injury report for Formosa Plastics Corporation, Texas is published. One employer, no account, unsubscribe in one click.
Site address
201 FORMOSA DR
City
POINT COMFORT
State
TX
ZIP
77978
Mailing
P.O. BOX 700, POINT COMFORT, TX 77978
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
1700
Ownership type
A

7 citations on file for this inspection.

1910.119 D03 I B

Other-than-serious 4 instances 1700 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process:    In the Poly Vinyl Chloride (PVC) Unit at Formosa Plastics Corporation located in Point Comfort, Texas the employer did not ensure the piping and instrument diagrams (P&ID's) were updated and accurate. Discrepancies included, but were not limited to:    a.  Car sealed valves not shown on P&ID such as HV-402, HV-406 and HV-420 on Reactors PR-401A-J.    b.  P&ID drawings were not updated and still showed mark ups for MOC 850, removal of sight glass and the associated piping on PC-304 Recycle VCM gas scrubber    c.  P&ID drawings were not updated and still showed mark ups for MOC 784, modifications on piping systems on PV-306 Crude VCM Storage Tank    d.  P&ID drawings were not updated and still showed mark ups for MOC 723, modifications on piping systems for PC-301 Caustic Scrubber
Recent events (2)
  • — I (O) $7000
  • — Z (S) $7000

1910.119 L04

Deleted Serious Gravity 10 1 instance 1700 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.119(l)(4): If a change covered by this paragraph results in a change in the process safety information required by paragraph (d) of this section, such information shall be updated accordingly.  In the PVC Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer did not update process safety information (P&ID) to reflect the changes made to the following systems including, but not limited to:  a.  MOC 850, Removal of sight glass and the associated piping on PC-304 Recycle VCM gas scrubber  b.  MOC 784, Modifications on piping systems on PV-306 Crude VCM Storage Tank  c.  MOC 723, Modifications on piping systems for PC-301 Caustic Scrubber
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 F01 II

Other-than-serious 1 instance 1700 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.119(f)(1)(ii): The employer's written operating procedures did not provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information in that operating limits were not adequately addressed:    In the Olefins Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer did not specify the safe operating limits (permit limits) for reactor opening conditions in the Reactor Cleaning procedure and did not include the consequences of deviations and steps required to correct or avoid deviations.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7000

1910.119 F04

Deleted Serious Gravity 10 6 instances 200 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel:   Employer did not have permanent or temporary confined space signage posted for employees to identify confined space locations.  Employees were potentially exposed to asphyxiations or trapped-in hazards in locations such as but not limited to:   a. 1399-E Quench Water Tower  b. 2404-F  c. 2402-F  d. 2005-F   e. 3300-E Stripper Demethanizer   f. 3301-E Striper Demethanizer
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.119 J04 I

Deleted Serious Gravity 10 2 instances 200 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment:  In the Olefins Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer did not ensure thickness monitoring was performed on process equipment, including but not limited to:  a.  Fuel Gas Filter 1010BL-B.  b.  Fuel Gas vent piping FG-331-1".
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.119 J05

Deleted Serious Gravity 10 3 instances 1700 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information in paragraph (d) of this section) in a safe and timely manner:  a.  In the Olefins-1 Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer operated process piping with deficient piping supports; such as but not limited to the FG331-1" Fuel Gas vent piping system.    b.  In the Ethylene Glycol Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer operated process equipment with broken sight glass; such as but not limited to the G-V-223 Regenerator Reboiler Condensate Tank.  c.  In the Olefins-1 Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer operated deficient process equipment such as but not limited to the Dryer Regen Heater 3122-C and control valve LV-31203.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.119 L01

Serious Gravity 10 2 instances 25 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
29 CFR 1910.119(l)(1): The employer did not establish written procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process:  In the PVC Unit at Formosa Plastics Corporation located in Point Comfort, Texas, the employer did not establish and implement written procedures to manage changes including but not limited to:  a.  Addition of valve V-468 to the piping system  b.  Alarm/interlock systems for reactors PR-401 A-J.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000