BATON ROUGE, LA —
OSHA Inspection: LOUISIANA FISH FRY PRODUCTS, LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LOUISIANA FISH FRY PRODUCTS, LTD. in 5267 PLANK ROAD, BATON ROUGE, LA 70805 (NAICS 311824). OSHA activity number 339863847.
Where did this inspection happen?
- Establishment
- LOUISIANA FISH FRY PRODUCTS, LTD.
- Site address
- 5267 PLANK ROAD
- City
- BATON ROUGE
- State
- LA
- ZIP
- 70805
- Mailing
- 5267 PLANK ROAD, BATON ROUGE, LA 70805
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311824
- Employees
- 55
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.179 J02
- Issued
- Oct 22, 2014
- Abate by
- Nov 6, 2014
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.179(j)(2): The following items were not be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: On or about July 24, 2014, in the blending area, the employer failed to ensure that hook and hoist chain inspections were performed frequently. Employees used the hoist 8 or 9 times a day to lift totes that weighed between 1,500 - 2,000 pounds.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.305 A02 I B
- Issued
- Oct 22, 2014
- Abate by
- Nov 6, 2014
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(i)(B): Temporary electrical power and lighting installations of 600 volts, nominal, or less was used for a period exceeding 90 days. On or about July 24, 2014, in the production line area, the employer failed to ensure that permanent electrical outlets were installed. Extension cords were being used a permanent wiring. 1) on line 4 it dropped down to the carton former machine. 2) on line 6 an extension cord was attached with zip ties and ran from the outlet along the machine and was being used as a power source for a 115 volt vibrator.