Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FORMED FIBER TECHNOLOGIES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FORMED FIBER TECHNOLOGIES, LLC in 125 ALLIED ROAD, AUBURN, ME 04211 (NAICS 326199). OSHA activity number 339887150.

Watch Formed Fiber Technologies, LLC — free Get an email when a new federal OSHA severe-injury report for Formed Fiber Technologies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
125 ALLIED ROAD
City
AUBURN
State
ME
ZIP
04211
Mailing
P.O. BOX 1300, AUBURN, ME 04211
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
254
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 4 instances 16 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $3020.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards from contact with robots:    In the Molding and Assembly Department the Pretrim Robots, P2, K4, K3, and K2 had the capability of reaching beyond the perimeter pressure sensitive safety mats, striking operators and other employees outside the safeguarded space.
Recent events (3)
  • — F (S) $3020
  • — C (S) $5500
  • — Z (S) $5500

1910.147 C06 I C

Serious Gravity 5 1 instance 45 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $3020.00 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:      Nonwoven Lines - Periodic inspections of the nonwoven lines did not include a representative number of observed employees.  The last two inspection cycles of the nonwoven lines included approximately 352 observations.  The same employee was observed in all but two observations.  The nonwoven department has approximately 45 operators.
Recent events (3)
  • — F (S) $3020
  • — C (S) $5500
  • — Z (S) $5500

1910.212 A01

Serious Gravity 5 3 instances 31 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $3020.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  5 Line, Second Loom, East End - The ingoing nip at the interface of the infeed rolls was not guarded.  b)  5 Line, Second Loom, West End - The ingoing nip at the interface of the infeed rolls was not guarded.  c)  Maintenance Shop - The rotating chuck on the "old" Bridgeport drill press was not guarded.
Recent events (3)
  • — F (S) $3020
  • — C (S) $5500
  • — Z (S) $5500

1910.215 B09

Serious Gravity 5 2 instances 27 exposed
Issued
Abate by
Penalty
Initial $5500.00 · Current $3020.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    Maintenance Shop - The tongue guards on the Dayton Pedestal Grinder were greater than one fourth of an inch from the abrasive wheel peripheries.
Recent events (3)
  • — F (S) $3020
  • — C (S) $5500
  • — Z (S) $5500

1910.219 D01

Serious Gravity 5 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $4400.00 · Current $2417.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):      Maintenance Shop - The belt/pulley assembly on a Bridgeport drill press was not guarded.
Recent events (3)
  • — F (S) $2417
  • — C (S) $4400
  • — Z (S) $4400

1910.147 C04 II

Repeat Gravity 5 3 instances 12 exposed
Issued
Abate by
Penalty
Initial $55000.00 · Current $30200.00 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):      a)  Molding & Assembly - The machine specific lockout/tagout procedure for performing maintenance and cleaning activities on jet cell 5 did not include isolating the electrical energy and applying a lock.      b)  Molding & Assembly -  The machine specific lockout/tagout procedure for performing maintenance and cleaning activities on jet cell 6 did not include isolating the electrical energy and applying a lock.    c)  Molding & Assembly -  The machine specific lockout/tagout procedure for performing maintenance and cleaning activities on jet cell A did not include isolating the electrical energy and applying a lock.        Formed Fiber Technologies, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 902258, citation number 2, item number 2 and was affirmed as a final order on 11/7/13, with respect to a workplace located at 1630 Ferguson Ct., Sidney, Ohio.    Formed Fiber Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii)(D), which was contained in OSHA inspection number 315717926, citation number 1, item number 1a and was affirmed as a final order on 10/6/11, with respect to a workplace located at 125 Allied Road, Auburn, Maine.
Recent events (3)
  • — F (R) $30200
  • — C (R) $55000
  • — Z (R) $55000

1910.147 C04 II D

Repeat Gravity 5 2 instances 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures:    In the following instances the written machine specific lockout/tagout procedures were not specific in that:      1. Each procedure required that the isolation of power be verified by attempting to start the equipment, when such an attempt was not possible for some of the equipment due to the loss of power to the control screens; and      2.  Each procedure provided instruction to verify that display indicators at the console are powered down.  Due to the possibility of a single console malfunction becoming a false reading of absence of voltage, an additional method of verification is necessary.  An additional method could include, but is not limited to, a visual verification of the absence of voltage on at least one other display powered by the same isolated energy source; or visual verification of a light which is activated by the absence of voltage to the console.    a)  Nonwoven Lines    b)  Molding and Assembly, Thermoformers        Formed Fiber Technologies, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(4)(ii), which was contained in OSHA inspection number 902258, citation number 2, item number 2 and was affirmed as a final order on 11/7/13, with respect to a workplace located at 1630 Ferguson Ct., Sidney, Ohio.    Formed Fiber Technologies, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 315717926, citation number 1, item number 1a and was affirmed as a final order on 10/6/11, with respect to a workplace located at 125 Allied Road, Auburn, Maine.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

1910.147 D

Repeat Gravity 5 12 instances 36 exposed
Issued
Penalty
Initial $27500.00 · Current $15100.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):     In the following instances electrical energy was not isolated and lockout devices were not affixed to energy isolation devices:       a)  While working on or cleaning the back side of jet cell 5.   b)  While working on or cleaning the back side of jet cell 6.   c)  While working on or cleaning the back side of jet cell A.     In the following instances energy isolating devices needed to control the energy were not isolated, lockout devices were not affixed, and energy isolation and deenergization was not verified:    d)  While cleaning the front side of jet cell 3.   e)  While cleaning the front side of jet cell 4.   f)  While cleaning the front side of jet cell 5.   g)  While cleaning the front side of jet cell 6.   h)  While cleaning the front side of jet cell 7.   i)   While cleaning the front side of jet cell 8.   j)  While cleaning the front side of jet cell 9.   k)  While cleaning the front side of jet cell 10.   l)  While cleaning the front side of jet cell A.       Formed Fiber Technologies, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 902258, citation number 1, item number 4 and was affirmed as a final order on 11/7/13, with respect to a workplace located at 1630 Ferguson Ct., Sidney, Ohio.
Recent events (3)
  • — F (R) $15100
  • — C (R) $27500
  • — Z (R) $27500

View FORMED FIBER TECHNOLOGIES, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339887150.