1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LINK SNACKS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LINK SNACKS INC. in 3302 HARLAN LEWIS ROAD, BELLEVUE, NE 68005 (NAICS 311423). OSHA activity number 339897498.

Watch Link Snacks INC. — free Get an email when a new federal OSHA severe-injury report for Link Snacks INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LINK SNACKS INC.
Site address
3302 HARLAN LEWIS ROAD
City
BELLEVUE
State
NE
ZIP
68005
Mailing
3302 HARLAN LEWIS ROAD, BELLEVUE, NE 68005
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311423
Employees
120
Ownership type
A

5 citations on file for this inspection.

1910.147 C07 I B

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3465.00 Reduced
29 CFR 1910.147(c)(7)(i)(B): Affected employee(s) was not instructed in the purpose and use of the energy control procedure.    At Link Snack, Inc. dba Jack Link's Beef Jerky 3302 Harlan Lewis Road, Bellevue, NE: The employer is failing to ensure that affected employee(s) are instructed in the energy control procedure. On or about July 22, 2014; employees working in the affect capacity per as defined by 29CFR 1910.147(b) were not trained on the purpose and function of Lockout/ Tagout.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1910.147 F03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew.    In the Kitchen Area on the Reitz Blender: The employer is failing to ensure that all employees cleaning/ washing out the Reitz Blender are afforded the protection of personal Lockout /Tagout.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3465.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:       In the Kitchen Area on the Reitz Blender: The employer is failing to ensure that one or more methods of guarding are used to protect employees are protected from the ingoing nip points and rotating parts created by the augers on the blender. On or about 7-22-2014 an employee suffered an amputation when contact was made with the rotating auger of the Blender during cleaning.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1910.333 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3465.00 Reduced
29CFR 1910.333(b)(1): The employees were not trained or made familiar with the safety-related work practices that pertain to their job assignments as required by 29CFR 1910.331 through 29CFR 1910.335:    Link Snacks, Inc. dba Jack Link's Beef Jerky: The employer is failing to provide training to employees on the electrical safety-related work practices that pertained to their job assignments. Maintenance employees are exposed to potential electrical shock, arc blast/ flash while conducting repair and/or service to machinery such as but not limited to Meat Grinders, Blenders and Extruders.
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1910.335 A01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:    Link Snacks, Inc. dba Jack Link's Beef Jerky: The employer is failing to ensure the use of electrical rated PPE for employees to when working on and or testing voltage of electrical circuits. Maintenance employees are exposed to potential electrical shock, arc blast/ flash while conducting repair and/or service to machinery such as but not limited to Meat Grinders, Blenders and Extruders.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View LINK SNACKS INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339897498.