CHICAGO, IL —
OSHA Inspection: HOODS CHICAGO
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HOODS CHICAGO in 4444 W. BELMONT AVE, CHICAGO, IL 60647 (NAICS 238220). OSHA activity number 339928780.
Where did this inspection happen?
- Establishment
- HOODS CHICAGO
- Site address
- 4444 W. BELMONT AVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60647
- Mailing
- 4444 W. BELMONT AVE, CHICAGO, IL 60647
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 1
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 D01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $200.00 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers were not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: a) South End of Storage Area - The stairs to access the lower level area on the south end of the building had five risers and no hand rails on either side. b) North End of Storage Area - The stairs to access the lower level area on the north end of the building had four risers and no hand rails on either side.
Recent events (3)
- — F (S) $200
- — C (S) $1200
- — Z (S) $1200
1910.23 E03 V C
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(3)(v)(c): Protection between top rail and floor, platform, runway, ramp, or stair treads, equivalent at least to that afforded by a standard intermediate rail: a) South End of Storage/Work Area - The second level where the fire extinguishers and other equipment are stored did not have a mid-rail.
Recent events (3)
- — F (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.36 G02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $100.00 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): The exit access was not at least 28 inches (71.1 cm) wide at all points: a) Storage/Work Space - The exit access in the middle of the storage space was not maintained at least 28 inches wide.
Recent events (3)
- — F (S) $100
- — C (S) $1200
- — Z (S) $1200
1910.253 B02 II
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $100.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, and gangways, or where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Storage/Work Area - Carbon Dioxide compressed cylinder tanks in storage were not secured from physical damage by passing or falling objects.
Recent events (3)
- — F (S) $100
- — C (S) $1600
- — Z (S) $1600
1910.253 B02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $100.00
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, were not in place, and on hand-tight: a) Storage/Work Area - Carbon Dioxide compressed cylinder tanks in storage did not have the valve protection caps in place and on hand tight.
Recent events (3)
- — F (S) $100
- — C (S) $0
- — Z (S) $0
1910.141 C01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in all places of employment: a) Storage/Work Area - The employer had a toilet that was not working or accessible.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): The employer had portable fire extinguishers that were not mounted, located, identified and readily accessible to employees without subjecting the employees to possible injury: a) North End of Storage Area - The ABC fire extinguisher was placed on the floor and not mounted.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238220)
LOS ANGELES, CA—2026-07-10
PRIME SC MECHANICAL INC.
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
PONCE, PR—2026-07-10
WILLIAM ECHEVARR�A ANDINO
MODESTO, CA—2026-07-09
R.L. FULLER, INC.
SAN JOSE, CA—2026-07-09
ROOTER HERO
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339928780.