Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIGHORN CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of BIGHORN CONSTRUCTION in BARONA RESORT & CASINO WRF ANOXIC TANK B IMPROVEMENT PROJECT, LAKESIDE, CA 92040 (NAICS 238110). OSHA activity number 339931172.

Watch Bighorn Construction — free Get an email when a new federal OSHA severe-injury report for Bighorn Construction is published. One employer, no account, unsubscribe in one click.
Site address
BARONA RESORT & CASINO WRF ANOXIC TANK B IMPROVEMENT PROJECT
City
LAKESIDE
State
CA
ZIP
92040
Mailing
925 POINSETTIA AVENUE, UNIT A4, VISTA, CA 92081
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
20
Ownership type
A

3 citations on file for this inspection.

1926.651 K01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions:       Located at the Anoxic Tank project, a 17 foot deep excavation inType B soil sloped at an angle of about 75 degrees to the horizontal (about 0.27 horizontal to 1 vertical) for about 48 feet from north fact of the trench was not inspected by a competent person exposing employees to the hazards of cave-ins.
Recent events (2)
  • — I (O) $1360
  • — Z (S) $1360

1926.652 A01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $0.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    Located at the Anoxic Tank project, the employer failed to provide to employees a protective system while working in a trench that was 17 foot deep excavation in Type B soil sloped at an angle of about 75 degrees to the horizontal (about 0.27 horizontal to 1 vertical) for about 48 feet from north face exposing the hazards of cave-ins.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1360

1910.1200 G08

Deleted Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8):  The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift.  (This provision is applicable to construction employment by 29 CFR 1926.59.):     At the project, there was no material safety data sheet for Swell Stop Primer used to seal the concrete walls in the trench.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339931172.