TULSA, OK —
OSHA Inspection: PRECISION FABRICATORS, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PRECISION FABRICATORS, INC. in 3839 N. OSAGE DRIVE, TULSA, OK 74127 (NAICS 332312). OSHA activity number 339980948.
Where did this inspection happen?
- Establishment
- PRECISION FABRICATORS, INC.
- Site address
- 3839 N. OSAGE DRIVE
- City
- TULSA
- State
- OK
- ZIP
- 74127
- Mailing
- 3839 N. OSAGE DRIVE, TULSA, OK 74127
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 36
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2900.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) : On or about October 01, 2014 and at times prior thereto, employees engaged in welding and fitting activities worked on the top of units at heights greater than four feet above concrete flooring without use of guardrails or fall protection. Employees were exposed to the hazard of falls.
Recent events (2)
- — I (S) $2900
- — Z (S) $4900
1910.146 C01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2900.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: On or about October 01, 2014, and at times prior thereto, the employer did not evaluate the workplace to determine if the spaces employees weld in were permit required confined spaces. Employees were exposed to hazards associated with confined spaces including, but not limited to asphyxiation and oxygen deficient atmospheres.
Recent events (2)
- — I (S) $2900
- — Z (S) $4900
1910.178 A06
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were maintained in a legible condition: On or about October 01, 2014, and at times prior to, the employer did not ensure data plate was on the Clark 146 forklift. Employees were exposed to the hazard of a falling load in the event the forklift was overloaded.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about October 01, 2014, and at times prior thereto, the employer did not ensure that each powered industrial truck operator had completed training. Employees were exposed to the hazard of being struck by/crushed by a falling load and or the forklift(s).
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.184 C09
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.184(c)(9): Employee(s) were not kept clear of load(s) suspended, or about to be lifted by sling(s): On or about October 01, 2014, and at times prior thereto, the employer allowed employees to work under suspended loads. Employees were exposed to the hazard of being struck by/crushed by a falling load.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.184 C06
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $4200.00 Reduced
General-duty citation text
29 CFR 1910.184(c)(6): Slings were not securely attached to their loads: On or about October 01, 2014, and at times prior thereto, the employer allowed employees to use makeshift fasteners,. The employer did not ensure the load was secure where makeshift fasteners were used, such as but not limited to: a) A shop made lifting eyebolt, b) A shop made lifting lug. Employees were exposed to the hazard of being struck by/crushed by a falling load.
Recent events (2)
- — I (S) $4200
- — Z (S) $7000
1910.184 F01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2900.00 Reduced
General-duty citation text
29 CFR 1910.184(f)(1): No ID tag markings on the wire rope slings: On or about October 01, 2014, and at times prior thereto, the employer did not ensure wire rope slings had ID tag markings attached. Employees were exposed to the hazard of being crushed by a falling load.
Recent events (2)
- — I (S) $2900
- — Z (S) $4900
1910.184 F05 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.184(f)(5)(i): Wire rope sling(s) that had ten or more randomly distributed broken wires in one rope lay, or five or more broken wires in one strand in one rope lay, were not immediately removed from service: On or about October 01, 2014 and at times prior thereto, the employer did not remove from service a wire rope sling that had broken wires throughout. Employees were exposed to the hazard of being crushed by a falling load.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.334 A02 II
- Issued
- Penalty
- Initial $2800.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: On or about October 01, 2014 and at times prior thereto, the employer did not remove from service a defective power cord for the foot pedal of a Geka Punch. Employees were exposed to the hazard of electrical shock.
Recent events (2)
- — I (S) $1200
- — Z (S) $2800
More inspections at PRECISION FABRICATORS, INC.
STUARTS DRAFT, VA—2014-03-06 00:00:00
PRECISION FABRICATORS INC
SAND SPRINGS, OK—2008-05-06 00:00:00
PRECISION FABRICATORS, INC.
STUARTS DRAFT, VA—2008-01-30 00:00:00
PRECISION FABRICATORS, INC.
STUARTS DRAFT, VA—2003-04-08 00:00:00
PRECISION FABRICATORS INC
RONDA, NC—1997-08-28 00:00:00
PRECISION FABRICATORS, INC.
View PRECISION FABRICATORS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
CAMDEN, NJ—2026-07-08
CENTRAL METALS, INC.
SACRAMENTO, CA—2026-07-07
MARTIN'S STEEL WORKS, INC
LOUISVILLE, KY—2026-07-01
69275 - NORTH AMERICAN INDUSTRIAL SUPPLY INC
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339980948.