Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BAYONNE DRYDOCK & REPAIR CORP.

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of BAYONNE DRYDOCK & REPAIR CORP. in MILITARY OCEAN TERMINAL/BAY, BAYONNE, NJ 07002 (NAICS 336611). OSHA activity number 340048222.

Watch Bayonne Drydock & Repair Corp. — free Get an email when a new federal OSHA severe-injury report for Bayonne Drydock & Repair Corp. is published. One employer, no account, unsubscribe in one click.
Site address
MILITARY OCEAN TERMINAL/BAY
City
BAYONNE
State
NJ
ZIP
07002
Mailing
P.O. BOX 240, BAYONNE, NJ 07002
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.37 B02

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    a) Pump room    Temporary and permanent employees were exposed to fire hazards, to include burn injuries and smoke inhalation, in that exit signs were not present to indicate the location of exit discharge.    Violation observed on or about 10/29/2014.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1915.89 O02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced
29 CFR 1915.89(o)(2)(i):   The employer did not train each employee who was, or may be, in an area where lockout/tags-plus systems were being used so they know the purpose and function of the employer's lockout/tags-plus program and procedures:    a)  Bayonne Drydock, Military Ocean Terminal, Bayonne, NJ    Temporary employees working on mechanical equipment in ballast tanks and motors in Pump room are exposed to hazardous residual energy, including but not limited to, electrical and mechanical energy sources.  Such workers were not trained on the host employer's lockout/tags-plus program and procedures.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1915.1001 K03 I

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced

Hazardous substances 9020

29 CFR 1915.1001(k)(3)(i): Before work in areas containing ACM and PACM was begun, the employer did not identify the presence, location, and quantity of ACM, and/or PACM, as required by 29 CFR 1915.1001(k)(1):    a) Bayonne Drydock and Repair Corp., 100 Military Ocean Terminal, Bayonne, NJ 07002     The employer did not provide information on the presence, location and quantity of asbestos-containing material (ACM) and presumed asbestos containing material (PACM) found in thermal system insulation on overhead pipes, for temporary and permanent employees working on electrical and mechanical equipment in the Pump room.      Violation observed on or about 10/29/2014.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1915.1001 K07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced

Hazardous substances 9020

29 CFR 1915.1001(k)(7)(i): Labels were not affixed to all products containing asbestos and to all containers containing such products, including waste containers;     a) Pump room    The employer did not label thermal system insulation (TSI) found on overhead pipes with signs identifying that asbestos containing material (ACM) or presumed asbestos containing material (PACM) was present.      Violation observed on or about 10/29/2014.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

1915.1001 K07 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $2700.00 Reduced

Hazardous substances 9020

29 CFR 1915.1001(k)(7)(ii): The employer did not include asbestos in the program established to comply with the Hazard Communication Standard (HCS) 29 CFR 1910.1200 and did not ensure that each employee had access to labels on containers of asbestos and safety data sheets, and was trained in accordance with the provisions of the HCS and paragraph (k)(9) of this section:    a) Pump room    The employer did not include asbestos in the hazard communication program and ensure that each employee had access to labels, safety data sheets, and is trained in the hazards of asbestos, including but not limited to cancer and lung disease.  Temporary and permanent employees working in the Pump room were exposed to asbestos containing material (ACM) or presumed asbestos containing material (PACM) in thermal system insulation (TSI) found on overhead pipes.      Violation observed on or about 10/29/2014.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500

View BAYONNE DRYDOCK & REPAIR CORP.'s full OSHA safety record →