PLEASANTVILLE, NY —
OSHA Inspection: FOREVER LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOREVER LLC in 359 BEDFORD RD., PLEASANTVILLE, NY 10570 (NAICS 238160). OSHA activity number 340160431.
Where did this inspection happen?
- Establishment
- FOREVER LLC
- Site address
- 359 BEDFORD RD.
- City
- PLEASANTVILLE
- State
- NY
- ZIP
- 10570
- Mailing
- 13 SHERWOOD ST, NORWALK, CT 06851
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 12/19/14 Location: 359 Bedford Rd. Pleasantville, NY 10507 a) Employees performing roofing work on a sloped roof with a minimum eave height of approximately 25 feet were not protected from falls by a personal fall arrest system or any other fall protection system.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B01
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about 12/19/14 Location: 359 Bedford Rd. Pleasantville, NY 10507 a) Employees used a 35 foot extension ladder which only extended 2 ft above its point of access to the roof. b) Employees used a 25 foot extension ladder which did not extended 3 ft above its point of access to the window. c) Employees used a 30 foot extension ladder which did not extended 3 ft above its point of access to the roof.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1060 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about 12/19/14 Location: 359 Bedford Rd. Pleasantville, NY 10507 a) Employees used Werner aluminium extension ladders that did not extend 3 feet above the landing level of the roof being accessed and used one Werner extension ladder which did not have the rope laynard required to be able to safely raise and lower the fly section. The emplyees were not trained by the employer in the hazards related to ladder use and the procedures to minimize such hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B16
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about 12/19/14 Location: 359 Bedford Rd. Pleasantville, NY 10507 a) Employees used a Werner 30 foot aluminum extension ladders to access a roof. The ladder was missing the laynard rope used to safely raise and lower the fly section.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340160431.