HOLMES BEACH, FL —
OSHA Inspection: GULFSIDE ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GULFSIDE ROOFING, INC. in 4408 GULF DRIVE, HOLMES BEACH, FL 34217 (NAICS 238160). OSHA activity number 340186204.
Where did this inspection happen?
- Establishment
- GULFSIDE ROOFING, INC.
- Site address
- 4408 GULF DRIVE
- City
- HOLMES BEACH
- State
- FL
- ZIP
- 34217
- Mailing
- 3219 63RD AVENUE EAST, BRADENTON, FL 34203
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a) For employees working at 4408 Gulf Drive in Holmes Beach, as observed on or about January 6, 2015. Employees were on the roof working without the use of a fall protection system in place. Employees were exposed to a fall hazard of approximately 9 feet 8 inches.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.404 B01 II
- Issued
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection. a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using power supplied through an extension cord that was not protected by a ground fault circuit interrupter.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.403 B01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(1)(iii): Safety of equipment was not determined on the basis of electrical insulation. a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using a reciprocating saw that was not inspected prior to use and had a severely damaged power cord at the point closest to the tool housing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 A02 II I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using an extension cord that passed through a doorway and was not protected to avoid damage
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) For employees working at 4408 Gulf Drive in Holmes beach, as observed on or about January 6, 2015. Employees were using power supplied through an extension cord that did not have proper strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at GULFSIDE ROOFING, INC.
PALMETTO, FL—2002-08-19 00:00:00
GULFSIDE ROOFING, INC
View GULFSIDE ROOFING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340186204.