FAIRFIELD, NJ —
OSHA Inspection: FLOWSERVE CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FLOWSERVE CORPORATION in 142 CLINTON ROAD, FAIRFIELD, NJ 07004 (NAICS 332911). OSHA activity number 340403138.
Where did this inspection happen?
- Establishment
- FLOWSERVE CORPORATION
- Site address
- 142 CLINTON ROAD
- City
- FAIRFIELD
- State
- NJ
- ZIP
- 07004
- Mailing
- 142 CLINTON ROAD, FAIRFIELD, NJ 07004
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 10000
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $7000.00 · Current $7000.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to. a) 142 Clinton Road Fairfield, NJ (Warehouse) a. The Employer did not ensure jack support was sufficient and pump secured in a stable position prior to permitting employees to work on it. Violation Occurred on or about 02/13/2015 b. Training on proper assembly procedure to include but not limited to utilizing jack support to stabilize the load was not provided thereby exposing workers to hazards of being struck/crushed by a 8,000lb boiler pump. Violation Occurred on or about 02/13/2015
Recent events (2)
- — I (O) $7000
- — Z (S) $7000
More inspections at FLOWSERVE CORPORATION
LYNCHBURG, VA—2021-10-28 00:00:00
FLOWSERVE CORPORATION
DUNBAR, WV—2019-08-27 00:00:00
FLOWSERVE CORPORATION
TANEYTOWN, MD—2019-03-29 00:00:00
FLOWSERVE CORPORATION
LYNCHBURG, VA—2017-10-02 00:00:00
FLOWSERVE CORPORATION
DUNBAR, WV—2017-05-16 00:00:00
FLOWSERVE CORPORATION
View FLOWSERVE CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 332911)
PRAIRIE DU SAC, WI—2026-06-25
MILWAUKEE VALVE COMPANY, LLC
SELMA, CA—2026-06-16
FRESNO VALVES & CASTINGS, INC.
PITTSBURGH, PA—2026-06-12
RED VALVE COMPANY
FRANKFORT, MI—2026-05-18
ROSS DECCO COMPANY
CONOVER, NC—2026-04-23
161108 - ENGINEERED CONTROLS INTERNATIONAL, INC.
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340403138.