CLEVELAND, OH —
OSHA Inspection: ALPHA PACKAGING HOLDINGS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALPHA PACKAGING HOLDINGS INC. in 14801 EMERY AVENUE, CLEVELAND, OH 44135 (NAICS 326199). OSHA activity number 340452994.
Where did this inspection happen?
- Establishment
- ALPHA PACKAGING HOLDINGS INC.
- Site address
- 14801 EMERY AVENUE
- City
- CLEVELAND
- State
- OH
- ZIP
- 44135
- Mailing
- 14801 EMERY AVENUE, CLEVELAND, OH 44135
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 190
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $5670.00 · Current $5670.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: At the time of inspection, the employer failed to ensure that: a) Energy control procedures for the grinders, including, but not limited to, Line 19 Battenfield Gloucester grinder, model # 1416 BP, serial # 141602-0292, included blocking the blades and the top of the grinder, b) Energy control procedures for the grinders, including, but not limited to, Line 20, included the release and lockout of the hydraulic/pneumatic pressure after the grinder has been opened.
Recent events (2)
- — I (S) $5670
- — Z (S) $5670
1910.147 C04 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: At the time of inspection, the employer failed to ensure that the energy control procedures included testing the grinders, including but not limited to Line 19 Battenfeld Gloucester grinder, model # 1416 BP, serial # 141602-0292, to verify the effectiveness of the lockout devices.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ALPHA PACKAGING HOLDINGS INC.
CLEVELAND, OH—2015-01-30 00:00:00
ALPHA PACKAGING HOLDINGS INC.
View ALPHA PACKAGING HOLDINGS INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source