ARLINGTON HEIGHTS, IL —
OSHA Inspection: CHRIS MCHUGH DBA MCHUGH BUILDERS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CHRIS MCHUGH DBA MCHUGH BUILDERS in 1228 N. YALE, ARLINGTON HEIGHTS, IL 60004 (NAICS 238130). OSHA activity number 340473115.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHRIS MCHUGH DBA MCHUGH BUILDERS
- Site address
- 1228 N. YALE
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60004
- Mailing
- 724 SHORELINE RD., BARRINGTON, IL 60010
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1903.19 C01
- Issued
- Jun 16, 2015
- Abate by
- Jul 20, 2015
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Chris McHugh dba McHugh Builders, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 1 05/15/2015 01 2a 05/15/2015 01 2b 05/15/2015 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — A (O) $400
- — I (O) $0
- — Z (O) $400
1926.451 F07
- Issued
- May 11, 2015
- Abate by
- Jul 31, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person: a) Employees required to erect a supported scaffold performed such activities without training or the direction of a competent person.
Recent events (3)
- — A (S) $1600
- — I (S) $600
- — Z (S) $1600
1926.451 B02
- Issued
- May 11, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(b)(2): Each scaffold platform and walkway was not at least 18 inches (46 cm) wide: (a) The platform that was provided by the employer for the employees to work from was only 12 inches wide.
Recent events (3)
- — A (S) $1600
- — I (S) $600
- — Z (S) $1600
1926.451 C02
- Issued
- May 11, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Supported scaffold legs did not bear on base plates.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- May 11, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were the employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) Employees performing carpentry work were exposed to falls of approximately 10 feet to the ground from an unprotected walkway on the second story overlooking the staircase. b) Employees performing carpentry work were exposed to falls of up to 15 feet from unprotected window openings on the second floor of the single family house. c) Employees were unprotected from the hazard of falling approximately 20.6 feet while sheeting the roof to a new single family house. d) Employees performing carpentry work were exposed to falls of approximately 8.3 feet from an unprotected open hole leading down into the basement of the house.
Recent events (3)
- — A (S) $2800
- — I (S) $1200
- — Z (S) $2800
1926.1052 C04
- Issued
- May 11, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members, shall be provided between the top rail of the stairrail system and the stairway steps. (A) A midrail was not provided between the top rail of the stairrail system and the stairway steps as required.
Recent events (3)
- — A (S) $1200
- — I (S) $600
- — Z (S) $1200
1926.1053 B01
- Issued
- May 11, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed.
Recent events (3)
- — A (S) $1600
- — I (S) $600
- — Z (S) $1600
More inspections in this industry (NAICS 238130)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340473115.