SOUTH PORTLAND, ME —
OSHA Inspection: POND COVE MILLWORK, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POND COVE MILLWORK, INC. in 53 WALLACE AVENUE, SOUTH PORTLAND, ME 04106 (NAICS 321918). OSHA activity number 340502640.
Where did this inspection happen?
- Establishment
- POND COVE MILLWORK, INC.
- Site address
- 53 WALLACE AVENUE
- City
- SOUTH PORTLAND
- State
- ME
- ZIP
- 04106
- Mailing
- 53 WALLACE AVENUE, SOUTH PORTLAND, ME 04116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 39
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): SAC Sueri Alfredo Wide Belt Sander - During the sanding belt changing operation the electrical and pneumatic energy isolation devices were not operated in such a manner as to isolate the machine from electrical and pneumatic energy sources.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: SAC Sueri Alfredo Wide Belt Sander - During the sanding belt changing operation locks were not applied on the electrical and pneumatic energy isolation devices.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: SAC Sueri Alfredo Wide Belt Sander - Prior to changing the sanding belt the authorized employee did not verify that isolation and deenergization of the machine had been accomplished.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: SAC Sueri Alfredo Wide Belt Sander - The written lockout procedure mounted on the machine did not outline the requirements for testing the machine to verify the effectiveness of electrical and pneumatic power isolation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: Establishment - The two foremen and one lead person who change the sanding belt on the SAC Sueri Alfredo wide belt sander were not adequately trained in the lockout procedure for that machine.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.147 C07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: Establishment - The employer did not certify that the two foremen and one lead person who are authorized to implement the lockout procedure were trained in the procedure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2450.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Establishment - The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.147 C05 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): Establishment - Locks did not indicate the identify of the employee applying them.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 A04
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: Hyster 50 fork truck - The employer did not receive written approval from the manufacturer of the Hyster 50 fork truck to attach a personnel platform to the forks of the truck.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.178 A05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with a front-end attachment other than a factory installed attachment, and the employer did not request that the truck be marked to identify the attachment, show the approximate weight of the truck and attachment combination, and show the capacity of the truck with attachment at maximum elevation with load laterally centered: Hyster 50 fork truck - The Hyster fork truck was not marked to identify the personnel platform attached to the forks, the approximate weight of the truck and personnel platform combination, and show the capacity of the truck with the personnel platform at maximum elevation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A03 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor: Installer's Work Station - The grounding pin was missing from the Porta Cable Sander, model 352VS.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Establishment - The last monthly visual inspection of fire extinguishers was November 2014.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at POND COVE MILLWORK, INC.
SACO, ME—2023-03-16 00:00:00
POND COVE MILLWORK, INC.
Dover, NH—1984-03-21
POND COVE MILLWORK INC
View POND COVE MILLWORK, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
WALNUT GROVE, KY—2026-07-07
69295 - MENZNER HARDWOODS CO
DEERWOOD, MN—2026-07-02
111521 - ACORN MILLWORK INC
MONTELLO, WI—2026-06-30
FLOORING AND EQUIPMENT LLC
LENOIR, NC—2026-06-26
161438 - WOODGRAIN, INC.
SALEM, MO—2026-06-09
CANOAK MISSOURI, LLC
More inspections in ME
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06
SHAW'S SUPERMARKETS
GORHAM, ME—2026-07-02
TOWN OF GORHAM
FARMINGTON, ME—2026-07-02
MCTA GENERAL CONSTRUCTION CORP
FARMINGTON, ME—2026-07-02
JC HOME IMPROVEMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340502640.