2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LMI CUSTOM MIXING, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LMI CUSTOM MIXING, LLC. in 804 BYESVILLE ROAD, CAMBRIDGE, OH 43725 (NAICS 325212). OSHA activity number 340523174.

Watch LMI Custom Mixing, LLC. — free Get an email when a new federal OSHA severe-injury report for LMI Custom Mixing, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
804 BYESVILLE ROAD
City
CAMBRIDGE
State
OH
ZIP
43725
Mailing
804 BYESVILLE ROAD, CAMBRIDGE, OH 43725
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325212
Employees
91
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $4900.00
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     a. Located in the facility at 804 Byesville Road in Cambridge Ohio, the employer did not ensure that energy control procedures required for employees to utilize while removing stuck rubber material that blocked the drop door on Mixer 1 were documented.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1910.147 C04 II

Serious Gravity 5 1 instance 11 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance.    a. Located in the facility at 804 Byesville Road in Cambridge Ohio, the employer did not ensure that the Mixer 1 Lock Out procedures were adequate to include (but not limited to) a specific statement of the intended use of the procedure; specific procedural steps for shutting down, isolating and controlling hazardous energy; specific procedural steps for the placement, removal and transfer of lockout devices; specific requirements for testing and verifying the effectiveness of the lockout devices another energy control measures for maintenance and contractors performing repairs and service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340523174.