COLUMBUS, OH —
OSHA Inspection: INSTALLED BUILDING PRODUCTS, LLC AKA IBP DBA EDWARDS/MOONEY & MOSES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of INSTALLED BUILDING PRODUCTS, LLC AKA IBP DBA EDWARDS/MOONEY & MOSES in 495 SOUTH HIGH STREET #50, COLUMBUS, OH 43215 (NAICS 238910). OSHA activity number 340525799.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 495 SOUTH HIGH STREET #50
- City
- COLUMBUS
- State
- OH
- ZIP
- 43215
- Mailing
- 1320 MCKINLEY AVE., SUITE B, COLUMBUS, OH 43222
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 1000
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B02
- Issued
- May 27, 2015
- Abate by
- Jun 16, 2015
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification. a. The relocatable power tap used on the mezzanine floor is not listed or labeled to be used for construction activities, it is listed and labeled for use in office and residential locations. The employees were exposed to fire and electrical contact hazards.
Recent events (2)
- — I (S) $3850
- — Z (S) $5500
1926.404 F06
- Issued
- May 27, 2015
- Abate by
- Jun 16, 2015
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a. On the Mezzanine floor the employees were using a reciprocating saw plugged in to a relocatable power tap that was plugged into an extension cord. The relocatable power tap was missing the grounding pin and was used to energize the saw, thereby exposing employees to contact with electrical current.
Recent events (2)
- — I (S) $3850
- — Z (S) $5500
1926.405 A02 II I
- Issued
- May 27, 2015
- Abate by
- Jun 16, 2015
- Penalty
- Initial $5,500 · Current $3,850 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage. a. The extension cord used to power a Dewalt reciprocating saw was damaged, thereby exposing employees to contact with electrical current.
Recent events (2)
- — I (S) $3850
- — Z (S) $5500
1926.855 F
- Issued
- May 27, 2015
- Abate by
- Jun 16, 2015
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1926.855(f): When floor arches are being removed, employees shall not be allowed in the area directly underneath, and such an area shall be barricaded to prevent access to it. a. While floor arches from the mezzanine were being removed the employer failed to block of the area below to ensure the safety of employees, thereby exposing them to a struck by/caught under hazard.
Recent events (2)
- — I (S) $4900
- — Z (S) $7000
1926.501 B01
- Issued
- May 27, 2015
- Abate by
- Jun 16, 2015
- Penalty
- Initial $38,500 · Current $26,950 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. Employees were working on the mezzanine floor with out fall protection. The open sided floor was two feet wide and the distance to the next lower level was 12 feet 4 inches. The floor below the mezzanine was covered in debris from the demolition, the employees were exposed to a 12 foot fall hazard. Installed Building Products was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 990714, citation number 1, item number 4 and was affirmed as a final order on January 14, 2015, with respect to a workplace located at 36 Forest Street, Lexington, MA 02421.
Recent events (2)
- — I (R) $26950
- — Z (R) $38500
More inspections at Installed Building Products, LLC AKA IBP DBA Edwards/Mooney & Moses
View Installed Building Products, LLC AKA IBP DBA Edwards/Mooney & Moses's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340525799.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.