Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FORT MASON CENTER

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FORT MASON CENTER in FORT MASON CENTER 2 MARINA BOULEVARD, SAN FRANCISCO, CA 94123 (NAICS 561210). OSHA activity number 340575463.

Watch Fort Mason Center — free Get an email when a new federal OSHA severe-injury report for Fort Mason Center is published. One employer, no account, unsubscribe in one click.
Establishment
FORT MASON CENTER
Site address
FORT MASON CENTER 2 MARINA BOULEVARD
City
SAN FRANCISCO
State
CA
ZIP
94123
Mailing
2 MARINA BOULEVARD BLDG. A, SAN FRANCISCO, CA 94123
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.243 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.243(c)(1): Abrasive wheels were used on portable grinders which were not provided with safety guards meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):    Pier 3 Maintenance Shop: On April 7, 2015, an employee suffered a laceration after the unguarded AvantiPro abrasive wheel on the Makita hand grinder broke and hit him in the right thigh.  The employee was taken to the hospital and received stitches and staples.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.335 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:    Fort Mason Center: The employer did not provide the electrician, who is routinely exposed to electrical hazards, with adequate electrical equipment.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.132 D02

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:  Fort Mason Center: The employer did not certify a written Personal Protection Equipment Hazard Assessment that identified what employees wear when performing a specific job task.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340575463.