Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BEST HAND SUPERIOR HOTEL LAUNDRY SERVICE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BEST HAND SUPERIOR HOTEL LAUNDRY SERVICE in 3305 WEST HARRISON STREET, CHICAGO, IL 60624 (NAICS 812332). OSHA activity number 340652635.

Watch Best Hand Superior Hotel Laundry Service — free Get an email when a new federal OSHA severe-injury report for Best Hand Superior Hotel Laundry Service is published. One employer, no account, unsubscribe in one click.
Site address
3305 WEST HARRISON STREET
City
CHICAGO
State
IL
ZIP
60624
Mailing
3305 WEST HARRISON STREET, CHICAGO, IL 60624
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812332
Employees
29
Ownership type
A

4 citations on file for this inspection.

1910.23 A08 II

Serious Gravity 1 1 instance 5 exposed
Issued
Penalty
Initial $2100.00 · Current $1470.00 Reduced
29 CFR 1910.23(a)(8)(ii): A floor hole cover of standard strength and construction. While the cover is not in place, the floor hole shall be constantly attended by someone or shall be protected by a removable standard railing.        a. Mechanical Room/Industrial Washer Machines Area - On or about May 22, 2015, the floor's drainage system was not maintained covered. Employees were thereby exposed to trip and falls.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.305 B01 I

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $2100.00 · Current $0.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.    a. South East Corner/End of Conveyor of Dirty Laundry - On or about May 22, 2015, the wiring for the BALDOR industrial electric motor was pulled away from the box and not protected from abrasion, thereby exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2100

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.   a. Behind the tunnel washer machines Area - On or about May 22, 2015, the outlet box was missing its cover plate, thereby exposing employees to electric hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.32 A02

Other-than-serious 2 instances 29 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.32(a)(2): Create an annual summary of injuries and illnesses recorded on the OSHA 300 A's Log Forms;   a. Front Office - On or about June 18, 2015, the employer had not created the annual summaries of injuries and illnesses (OSHA 300 A's log forms on 2013 and 2014) for previous years.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340652635.