COLORADO SPRINGS, CO —
OSHA Inspection: BEST HOMES, LTD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BEST HOMES, LTD in 6286 SAN MATEO DRIVE, COLORADO SPRINGS, CO 80911 (NAICS 238310). OSHA activity number 340802420.
Where did this inspection happen?
- Establishment
- BEST HOMES, LTD
- Site address
- 6286 SAN MATEO DRIVE
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80911
- Mailing
- 902 DESERT CIRCLE, FOUNTAIN, CO 80817
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) On or about July 22, 2015, employees were working from a scaffold, which was not inspected by a competent person before use, exposing them to falls of approximately 14 feet.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a) On or about July 22, 2015, employees working from a supported scaffold, where the support legs were not placed on an adequate foundation, were exposed to falls of 14 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) On or about July 22, 2015, employees working from a scaffold without the benefit of a fall protection system, were exposed to falls of approximately 14 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: (a) On or about July 22, 2015, employees working from a supported scaffold, where the support legs were not braced at the bottom to prevent the legs from moving, were exposed to falls of 14 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238310)
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
IRVINE, CA—2026-07-10
COAST BUILDING PRODUCTS
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
DOWNINGTOWN, PA—2026-07-09
CAPITAL INTERIOR, LLC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340802420.