Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN BUILDING CONTRACTORS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN BUILDING CONTRACTORS INC. in 1446 CROWFOOT LANE, MINOOKA, IL 60447 (NAICS 238160). OSHA activity number 340848852.

Watch American Building Contractors INC. — free Get an email when a new federal OSHA severe-injury report for American Building Contractors INC. is published. One employer, no account, unsubscribe in one click.
Site address
1446 CROWFOOT LANE
City
MINOOKA
State
IL
ZIP
60447
Mailing
3550 SALT CREEK LANE, ARLINGTON HEIGHTS, IL 60004
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2940.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    Employees performing residential roofing operations were exposed to a 9.7 foot fall when the employer failed to ensure the extension ladders used for access/egress extended at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $6460.00 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.    Employees performing residential roofing operations were exposed to a 9.7 foot fall when the employer failed to ensure that fall protection was utilized.     American Building Contractors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 109296, citation number 1, item number 1 and was affirmed as a final order on December 22, 2011, with respect to a workplace located at 324 Adams Court Vernon Hills, IL 60061.     American Building Contractors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 109296, citation number 1, item number 1 and was affirmed as a final order on December 22, 2011, with respect to a workplace located at 926 Monroe Court Vernon Hills, IL 60061.     Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (R) $6460
  • — Z (R) $10780

View AMERICAN BUILDING CONTRACTORS INC.'s full OSHA safety record →