TILTON, NH —
OSHA Inspection: AMERICAN CUSTOM DESIGN WOODWORKING INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of AMERICAN CUSTOM DESIGN WOODWORKING INC. in 168 SANDBORN RD, TILTON, NH 03276 (NAICS 321999). OSHA activity number 340925643.
Where did this inspection happen?
- Establishment
- AMERICAN CUSTOM DESIGN WOODWORKING INC.
- Site address
- 168 SANDBORN RD
- City
- TILTON
- State
- NH
- ZIP
- 03276
- Mailing
- 168 SANBORN RD, TILTON, NH 03276
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 3
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
04352440D615
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Location: Spray Booth Area a. On or about September 17, 2015, an employee had not had a medical evaluation prior to initial use of respirators for activities such as, but not limited to, spraying lacquer and sealants on wooden doors and cabinets. The employee wears a 3M half-face respirator with OV cartridges for potential exposure to respiratory hazards including: Diethylene glycol monoethyl ether, 2-butoxyethanol, and titanium dioxide.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
04352440M328
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: Location: Spray room area a. Employees wearing voluntary use half-face respirators had not been provided with information and training as required in Appendix D of the respiratory protection standard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the materials: Location: Facility on bench: a. On or about September 17, 2015, a Delta Rockwell radial saw's lower blade portion was not guarded.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.213 I01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the saw blade were not enclosed or guarded: Location: Main woodworking floor a. Shop - On or about September 17, 2015, a large green bandsaw next to the planer had non-working portions of the blade not guarded to prevent accidental contact during operation. b. Shop - On or about September 17, 2015, a large green bandsaw next to the wood storage room had non-working portions of the blade not guarded to prevent accidental contact during operation.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
0435244092109211D615
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Location: Facility. a. On or about September 17, 2015, the employer did not develop, implement and maintain a written hazard communication program for employees working with and around hazardous chemicals including but not limited to: Diethylene glycol monoethyl ether, 2-butoxyethanol, titanium dioxide, and hard and soft woods dusts.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0435244092109211D615
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet in the workplace for each hazardous chemical which they use: Location: Facility. a. On or about September 17, 2015, the employer did not obtain safety data sheets for hazardous chemicals used at the facility. Hazardous chemicals at this facility include but are not limited to: Diethylene glycol monoethyl ether, 2-butoxyethanol, titanium dioxide, and hard and soft wood dusts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0435244092109211D615
General-duty citation text
29 CFR 1910.1200(h)(2): The employer did not inform employees information that included the requirements of 29 CFR 1910.1200(h)(2)(i) through (h)(2)(iii): Location: Facility a. On or about September 17, 2015, the employer did inform employees about hazard communication and chemical hazards present in the workplace for employees working with and around hazardous chemicals including but not limited to: Diethylene glycol monoethyl ether, 2-butoxyethanol, titanium dioxide, and hard and soft woods.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
0435244092109211D615
General-duty citation text
29 CFR 1910.1200(h)(3): The employer did not provide training for employees that included the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv): Location: Facility. a. On or about September 17, 2015, employees exposed to chemicals in their workplace were not provided with effective information and training on hazardous chemicals in their work area. Additionally training did not include GHS 2012 information. Hazardous chemicals at this facility include but are not limited to: Diethylene glycol monoethyl ether, 2-butoxyethanol, titanium dioxide, and hard and soft wood dusts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at AMERICAN CUSTOM DESIGN WOODWORKING INC.
TILTON, NH—2015-10-27 00:00:00
AMERICAN CUSTOM DESIGN WOODWORKING INC.
View AMERICAN CUSTOM DESIGN WOODWORKING INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321999)
NORTH WILKESBORO, NC—2026-07-07
161501 - MILLER BEE SUPPLY, INC.
MIAMI, FL—2026-06-26
FLORIDA LUMBER COMPANY
PLATO, MN—2026-06-25
111471 - GREAT OAK EQUINE
PLATO, MN—2026-06-25
111470 - GREAT OAK EQUINE
DULUTH, MN—2026-06-23
111455 - NORTHSHORE WOOD PRODUCTS INC
More inspections in NH
CONCORD, NH—2026-07-10
C.C. TOMATOES
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
NORTHFIELD, NH—2026-07-03
JP PEST SERVICES
CONCORD, NH—2026-07-01
REYES CARPENTRY, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340925643.