GROVE CITY, OH —
OSHA Inspection: CH BRADSHAW CO.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CH BRADSHAW CO. in 2004 HENDRIX DR, GROVE CITY, OH 43123 (NAICS 336390). OSHA activity number 340939875.
Where did this inspection happen?
- Establishment
- CH BRADSHAW CO.
- Site address
- 2004 HENDRIX DR
- City
- GROVE CITY
- State
- OH
- ZIP
- 43123
- Mailing
- 2004 HENDRIX DR, GROVE CITY, OH 43123
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 21
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.106 E02 III
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(iii): "Separation and protection." Areas in which flammable liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided. a. At the workplace in the shed area, methanol was dispensed daily by employees from a steel drum without having drains or containment means in place to controls spills.
Recent events (2)
- — I (S) $0
- — Z (S) $1700
1910.106 E06 II
- Issued
- Abate by
- Penalty
- Initial $1700.00 · Current $1190.00 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with. a. At the workplace in the shed area, methanol was dispensed by employees, several times daily, from a steel drum into a plastic container, without being electrically interconnected by means of a bonding wire or grounded. Methanol was pumped from the drum while employees held the plastic container. b. At the workplace in the outdoor truck area, methanol was dispensed by employees, several times daily, from a plastic container into propane tanker trucks, without being electrically interconnected by means of a bonding wire or grounded. Methanol was dumped into the tanks through the top hatch or vent prior to filling with propane.
Recent events (2)
- — I (S) $1190
- — Z (S) $1700
More inspections at CH BRADSHAW CO.
GROVE CITY, OH—2013-09-21 00:00:00
CH BRADSHAW CO.
View CH BRADSHAW CO.'s full OSHA safety record →
More inspections in this industry (NAICS 336390)
CIRCLEVILLE, OH—2026-07-07
ENGINEERED PLASTIC COMPONENTS INC.
BENTON HARBOR, MI—2026-06-30
LINAMAR STRUCTURES GROUP
NEW HUDSON, MI—2026-06-30
COSMA BODY ASSEMBLY MICHIGAN
OGDEN, UT—2026-06-23
AUTOLIV ASP INC
EL PASO, TX—2026-05-28
HANON SYSTEMS LLC (CLIMATE)
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source