ROME, NY —
OSHA Inspection: LOGOPLASTE USA SYRACUSE, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LOGOPLASTE USA SYRACUSE, LLC in 1 OLIVE GROVE STREET, ROME, NY 13441 (NAICS 326160). OSHA activity number 340987007.
Where did this inspection happen?
- Establishment
- LOGOPLASTE USA SYRACUSE, LLC
- Site address
- 1 OLIVE GROVE STREET
- City
- ROME
- State
- NY
- ZIP
- 13441
- Mailing
- 1 OLIVE GROVE STREET, ROME, NY 13441
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326160
- Employees
- 33
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2231.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the establishment, on or about 10/14/15: Annual inspections of the company's energy control procedures were not conducted to ensure that the procedure and requirements of the standard were being followed. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2231.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) At the establishment, on or about 10/14/15: Process tech employees had not received lockout/tagout training as authorized employees. Process tech employees are required to perform set up and changeover operations on equipment but had only received awareness training as affected employees. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $2231.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and pinch points: a) Production Area, on or about 10/14/15: The Gaylord tipper for the Sidel SBO 4/2 preform was not adequately guarded in that the gates around the tipper were not interlocked. b) Production Area, on or about 10/14/15: Ingoing nip points on the transfer belts and pulleys on the bottle exit end conveyor line for the Sidel SBO 4/2 Line 6 were not guarded. c) Production Area, on or about 10/14/15: Pinch points on two pressure heads at the B&W leak tester station were not guarded. d) Production Area, on or about 10/14/15: Pinch points on two pressure heads at the Kautex leak tester station Line 3 were not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $2231.25
- — Z (S) $2975
1910.37 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Warehouse, on or about 10/14/15: There were no exit directional signs in the warehouse to indicate the direction of travel to the nearest exit. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at LOGOPLASTE USA SYRACUSE, LLC
ROME, NY—2010-03-04 00:00:00
LOGOPLASTE USA SYRACUSE LLC
ROME, NY—2010-03-04 00:00:00
LOGOPLASTE USA SYRACUSE LLC
View LOGOPLASTE USA SYRACUSE, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326160)
LUXEMBURG, WI—2026-06-15
N.E.W. PLASTICS CORP.
PENDERGRASS, GA—2026-06-11
RESILUX AMERICA, LLC
VERONA, PA—2026-06-03
ALTIUM PACKAGING
IRVINE, CA—2026-05-07
JSN INDUSTRIES, INC.
FONTANA, CA—2026-04-22
VPET USA INC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340987007.