Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN COLOR LABS OF TEXAS, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN COLOR LABS OF TEXAS, LTD. in 435 ISOM ROAD STE 220, SAN ANTONIO, TX 78216 (NAICS 323110). OSHA activity number 341081586.

Watch American Color Labs OF Texas, LTD. — free Get an email when a new federal OSHA severe-injury report for American Color Labs OF Texas, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
435 ISOM ROAD STE 220
City
SAN ANTONIO
State
TX
ZIP
78216
Mailing
435 ISOM ROAD STE 220, SAN ANTONIO, TX 78216
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
16
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by flying projectiles:      Mounting Department:  On or about November 18, 2015, employees was exposed to the hazard of being stuck by flying projectiles, while operating a compressed air blow-off gun to clean prints prior to lamination.  The compressed air used by this blow-off gun was transported above grade via 1/2" SCH 40 PVC Charlotte Pipe at an operating pressure of approximately 103.8 p.s.i.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.37 B02

Serious Gravity 1 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  On or about November 18, 2015, employees were exposed to a fire hazard, due to all emergency exits not marked with exit signs, limiting the means of egress.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.37 B07

Serious Gravity 1 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(7): Each exit sign did not have the word "Exit" in plainly eligible letters not less than six inches (15.2 cm) high, with the principal strokes of the letters in the word "Exit" not less than three fourths of an inch (1.9 cm) wide:  Fabric Room:  On or about November 18, 2015, employees were exposed to a fire hazard, due to a hand written emergency exit sign, that did not meet design specifications.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  Mounting Department:  On or about November 18, 2015, an employee was exposed to the hazard of being struck by flying projectiles, while operating a compressed air blow-off gun to clean prints prior to lamination.  The tip pressure of the blow-off gun was greater than 30 p.s.i.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.303 G01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:  Fabric Room:  On or about November 18, 2015, employees were exposed to an electrical hazard, while not having unobstructed access to a wall mounted Siemens Indoor Load Center, due to electrical support equipment permanently installed at grade.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.334 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  Mounting Room:  On or about November 18, 2015, employees were exposed to an electrical hazard, while operating a Neolt Trimmer, Model EL PW TRIM 130, with a 120 Vac power cord that had damage to the outer jacket, thus exposing the internal wiring.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

View AMERICAN COLOR LABS OF TEXAS, LTD.'s full OSHA safety record →