1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: LIBERTY PUMPS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of LIBERTY PUMPS INC. in 7000 APPLE TREE AVENUE, BERGEN, NY 14416 (NAICS 333911). OSHA activity number 341296366.

Watch Liberty Pumps INC. — free Get an email when a new federal OSHA severe-injury report for Liberty Pumps INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LIBERTY PUMPS INC.
Site address
7000 APPLE TREE AVENUE
City
BERGEN
State
NY
ZIP
14416
Mailing
7000 APPLE TREE AVENUE, BERGEN, NY 14416
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333911
Employees
175
Ownership type
A

6 citations on file for this inspection.

1910.146 C01

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $4500.00
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  a) New Powder Coating Curing Oven - On or about 3/4/16, the employer did not evaluate the new powder coating curing oven to determine whether or not it was a permit-required confined space.  Employees enter the oven once a week to pick up parts that have fallen off.  b) New Powder Coating Parts Washer - On or about 3/4/16, the employer did not evaluate the new powder coating parts washer to determine whether or not it was a permit-required confined space.  Employees enter the parts washer 2-3 times per week to pick up parts that have fallen.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.146 E01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $4500.00
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:    a) New Powder Coating Curing Oven - On or about 3/4/16, employees entered the oven to clean up fallen parts.  An entry permit was not completed.      b) New Powder Coating Parts Washer - On or about 3/4/16, employees entered the parts washer to clean up fallen parts.  An entry permit was not completed.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.146 G01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $0.00 Reduced
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:    a) New Powder Coating Curing Oven - On or about 3/4/16, the employer did not provide training to employees who enter the oven to pick up parts that have fallen.  Employees enter the oven at least once per week.    b) New Powder Coating Parts Washer - On or about 3/4/16, the employer did not provide training to employees who enter the parts washer to pick up parts that have fallen.  Employees enter the parts washer 2-3 times per week.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.147 C04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $4500.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  New Powder Coating Line - On or about 3/7/16,  employees perform servicing and maintenance activities on equipment including, but not limited to, the Powder Coating Curing Oven which had multiple energy sources including heat, and electric were not protected from unexpected energization or start-up. Specific procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were performing servicing or maintenance.    b) New Powder Coating Line - On or about 3/7/16, employees perform servicing and maintenance activities on equipment including, but not limited to, the Powder Coating Parts Washer which had multiple energy sources including heat, and electric were not protected from unexpected energization or start-up.  Specific procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were performing servicing or maintenance.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4500
  • — Z (S) $4500

1910.147 C07 I A

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    a)  New Powder Coating Line- On or about 3/7/16,  employees performed servicing and/or maintenance and were exposed to injury from unexpected energization of equipment such as, but not limited to, the powder coating curing oven and the powder coating parts washer which have multiple energy sources.  Employees had not received training in the recognition of applicable hazardous energy sources, and the methods necessary for energy isolation and control.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.151 C

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $3600.00 · Current $2500.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) New Powder Coating Line - On or about 3/4/16, an emergency eyewash station was not provided for employees working with Gardoclean S5657, a corrosive material.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3600

View LIBERTY PUMPS INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341296366.